SCANMASKIN SCAN COMBIFLEX 650 Manual página 61

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

SCAN COMBIFLEX 650
F0003
Over tempera-
 The internal temperature in the inverter is above 135°C
ture
F0004
Short circuit in
 The cable to the motor has been damaged
motor
 The motor has been damaged
F0006
Under voltage
F0007
Speed refer-
ence error
F0016
Protective earth
 The cable to the motor has been damaged
failure
 The motor has been damaged
 Water have entered the motor
F0018
Internal error
F0021
F0022
Power supply
phase fault
F0034
Motor phase
 One of the three phases to the motor is missing. This
fault
Table 5.2 Error codes
Alarm codes starts with "A" and fault codes starts with "F". The machine will be operational if an alarm
code is present but not when an fault code is present.
The following table describes the access for the task.
Abbrevia-
Person
tion
O
Machine Operator
E
Electrician
S
Scanmaskin certified service technician
Table 5.3
Access rights for different persons
www.scanmaskin.com
(275°F). This could be caused by faulty ventilation in
the electrical cabinet.
could be due to damage to the motor cable or to the
motor.
 Inspect the motor cable
 Inspect the motor connection
 Contact Scanmaskin Sweden AB
 Inspect the motor cable
 Inspect the motor connection
 Contact Scanmaskin Sweden AB
Contact Scanmaskin Sweden AB
 Inspect the motor cable
 Inspect the motor connection
 Contact Scanmaskin Sweden AB