RTN/M2
Mounting of load cells up to a max. capacity of 4.7 t (see Fig. 7.1):
Remove the anti‐liftoff device by undoing the 2 hexagonal screws
Loosen the lateral stops
Use a suitable lifting device to lift the respective tank base by approx.
10 mm
Undo the centering discs
Remove the dummy with the mounting base of the RTN by lifting lightly
and withdrawing to one side (for pendulum bearing version, with pendulum
bearing)
Remove mounting from dummy and fit to load cell; tightening torque of the
4 screws: 4 Nm
Secure and position load cell with mounting base by means of centering
discs on the lower module plate. Apply the enclosed grease to the load in-
troduction parts of the load cell.
With the pendulum bearing version, position the pendulum bearing on the
load cell. Also apply grease.
Slowly lower the tank while making sure that the load buttons engage with
the corresponding seats without suffering damage.
Vertical module alignment by inserting or removing the five 1‐mm‐thick
spacer plates underneath the upper module plate.
Mount and adjust the anti‐liftoff device by inserting plates underneath such
that an air gap of about 1 mm results (see Fig. 7.1) with the tank empty.
First adjust and then lock the horizontal stops. The U‐shaped bracket ac
counts for the stiffness of the stops and has to be fastened with the stop
screws. Please refer to the Specifications in Chapter 5 for the maximum
permissible horizontal shifts (distance from the stops). The stay rods al-
ready have been adjusted at the factory to ensure that the load introduc-
tion parts are aligned with the load cell in the rod direction. Should a read-
justment prove necessary, the rod end bearings subsequently have to be
carefully locked.
Mounting of load cells up to a max. capacity of 10 t, 22 t and 33 t (see
Fig. 7.2):
Remove the anti‐liftoff device by undoing the 2 hexagonal screws
Use a suitable lifting device to lift the respective tank base by approx.
10 mm
Remove the load cell dummy without the mounting base with thrust piece
by lifting lightly and withdrawing to one side (for pendulum bearing version,
with pendulum bearing)
A1867-2.0 en/de/fr/es
13
HBM