Operation; First Use - SATA jet 1000 ROB RP/HVLP Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 137
SATA ROB Automatic Gun Operating Instructions
EN
Notice!
To use the automatic gun again without material circulation, screw the
dummy plug in as far as it will go. Secure with Loctite 242.
Check for any damage and soiling and replace corresponding compo-
nents as required.
9.

Operation

Loose screws can cause damage to parts or result in malfunctions.
→ Tighten all screws by hand and check that they are screwed tight.

9.1. First use

The automatic gun is supplied fully assembled and ready for operation.
After unpacking, check:
■ Automatic gun damaged.
■ Scope of supply complete (see chapter 5).
Using soiled compressed air can cause malfunctions.
→ Use clean compressed air. For example with SATA filter 444 (Art. No.
92296).
■ Check that all screws are screwed tight.
■ Screw the fluid tip tight.
■ Rinse material passages with a suitable cleaning solution (see chapter
11).
■ Align the air cap.
■ Connect the control air (min. 3 bar).
■ Connect flat and round fan air.
■ Connect the material supply.
Notice!
Test air caps are available from SATA to help adjust the spraying pa-
rameters (see chapter 13).
126
Attention!
Attention!
Tabla de contenido
loading

Tabla de contenido