SETUP MENU

1. Press the Up and Down buttons
simultaneously for three seconds
to enter the setup menu.
2. Press the Up or Down button to
change the option.
3. Press the Up and Down buttons
simultaneously and briefly to
advance to the next parameter.
Parameter
Minimum setpoint
Maximum setpoint

IN CASE OF DIFFICULTY

PROBLEM
Thermostat is hot.
Wrong temperature is
displayed.
Display disappears and
reappears after a few
minutes.
Display looks faded when
heating is activated.
Options
5°C - 30°C (41°F - 86°F)
NOTE: The minimum setpoint cannot be
set higher than the value set for
the maximum setpoint.
5°C - 30°C (41°F - 86°F)
NOTE: The maximum setpoint cannot be
set lower than the value set for the
minimum setpoint.
This is normal unless the thermostat is too hot to touch. Ensure that the heater
capacity does not exceed the thermostat's maximum load.
Avoid any of the following conditions:
The thermostat is exposed to an air draft.
The thermostat is located near or above a heat source such as a light dimmer.
The thermal circuit breaker on the heater has temporarily opened. This can happen
if the heater is obstructed by furniture or curtain and has overheated, or if the
thermal circuit breaker is defective or too sensitive.
The heater capacity is probably less than the thermostat minimum load
requirement. The thermostat cannot be used below that rating.
4. When the last parameter is dis-
played, press the Up and Down
buttons for three seconds to save
any changes and exit the menu.
NOTE: If you do not press any button
for 15 seconds, the thermostat
will automatically save any
changes you have made and
will then return to its normal
display.
SOLUTIONS
5
RLV3150
Display and
default setting
33-00209ES—05