GENERAL INSTRUCTIONS
The system and installation must comply with all state and local laws
and regulations.
PERFORMANCE DATA
Flow Rate: ......................................................... 1.0 GPM (3.8 LPM)
Min./Max. Operating Pressure ............25 psi/125 psi (172 - 862 kPa)
Min./Max. Operating Temperature .................35°F/100°F (2°C/38°C)
Replacement Cartridge ...........................................GACI-SS Series A
Capacity .................................................1,000 Gallons (3,785 Liters)
NOTICES
Install this filter on a cold water line only. Use in ambient temper-
atures of between 35° and 100°F (2°-38°C) and with water tem-
peratures between 35° and 100°F (2° - 38°C). Water pressure
maximum is 125 psi (862 kPa).
Protect the unit from direct sunlight and freezing temperatures.
Do not use pipe dope or similar compounds. They can ruin plas-
tic. Use Teflon™ tape to seal pipe thread joints.
Intended for indoor, non-commercial use only.
For extended periods of non-use turn the water off and remove
the filter cartridge. Place the cartridge in a plastic bag, seal it,
and refrigerate it.
Safety glasses must be worn during installation.
This unit is not designed to filter sulfur (rotten egg odor). Use
of carbon filters to treat sulfur may intensify taste and odor
problems.
Before using the water, flush the new filter for 30 minutes.
Run drinking or cooking water for 10 seconds prior to collecting
the water for use.
The contaminants effected by this filtering system are not neces-
sarily present in your water.
This filter is not a water purifier and is not intended for use with
contaminated water.
Comply with all state and local laws regarding the installation of
water treatment devices.
Use only OMNI filter cartridges with this housing, or warranty is
void.
"Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system."
For conditions of use, health claims, and replacement parts, see
the performance data sheet. Follow the instructions in this man-
ual to ensure unit performance.
When to change the filter cartridge
The GACI-SS Series A Cartridge should be changed after 1,000 gal-
lons of water use or every 6 months (whichever comes first).
TM
EI DU PONT DE NEMOURS and Company Corporation, Wilmington Delaware.
®
INSTALLATION INSTRUCTIONS
Choose and Mark Location:
1.Choose a location and position the filter housing bracket on the
wall of the cabinet nearest the cold water line beneath the sink.
Leave a 3" minimum clearance between the bottom of the filter
housing and the floor of the cabinet. See Figure 1.
Figure 1
2. Mark the bracket slots on the wall, drill a hole at each of the two
marks, and insert the mounting screws. Leave each screw head
1/4" out from the wall. Install the filter assembly onto the
mounting screws.
3. Locate and turn off the cold water inlet valve.
4. Put a pan under the cold water valve and disconnect the cold
water pipe or tubing from the inlet valve. See Figure 2.
Figure 2
Undersink Water
Filter System
INSTALLATION INSTRUCTIONS
Model SFM2 Series A
Locate
Choose the Housing
the Cold
Location and Mark
Water
the Screw Locations
Line
Close the Cold
Water Inlet Valve
©2002, Omnifilter Printed in U.S.A. 1000001406 (Rev. 10/4/02)
Put a Pan Under the
Cold Water Pipe
or Tubing to
Collect the Water
from the Pipe.
Disconnect the
pipe or Tubing.
Tabla de contenido
loading

Resumen de contenidos para Omnifilter A Serie

  • Página 1 The GACI-SS Series A Cartridge should be changed after 1,000 gal- lons of water use or every 6 months (whichever comes first). Figure 2 EI DU PONT DE NEMOURS and Company Corporation, Wilmington Delaware. ©2002, Omnifilter Printed in U.S.A. 1000001406 (Rev. 10/4/02)
  • Página 2 Figure 7 System tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of taste, odor and chlorine. For further operating, installation, or maintenance assistance: Call Omnifilter Customer Service at 800-937-6664; www.omnifilter.com, Figure 5 Delavan, WI 53115...
  • Página 3 ® à installer sous l’évier 293 Wright St. • Delavan, WI 53115 Phone: 1-800-937-6664 INSTRUCTIONS D’INSTALLATION www.omnifilter.com Modèle SFM2, série A INSTRUCTIONS GÉNÉRALES INSTRUCTIONS D’INSTALLATION Ce système et son installation doivent être conformes à tous les règlements en vigueur dans la province et dans la municipalité.
  • Página 4: Branchement Des Tubes

    Pour de plus amples renseignements concernant le fonctionnement, l’installation ou l’entretien : Appeler le service à la clientèle Omnifilter en composant le (800) 937-6664; ww.omnifilter.com Figure 5 Delavan, WI 53115...
  • Página 5: Instrucciones Generales

    ® para debajo del fregadero 293 Wright St. • Delavan, WI 53115 Phone: 1-800-937-6664 INSTRUCCIONES DE INSTALACIÓN www.omnifilter.com Modelo SFM2, Serie A INSTRUCCIONES GENERALES INSTRUCCIONES DE INSTALACIÓN El sistema y su instalación deben cumplir con todas las leyes y normas estatales y locales.
  • Página 6 Norma 42 de ANSI/NSF para la reducción de sabor, olor y cloro. Para obtener más información sobre la operación, instalación o el mantenimiento: Llame al Departamento de Servicio al Cliente de Omnifilter: 800-937-6664; www.omnifilter.com Delavan, WI 53115 Figura 5...
  • Página 7: Assembly Drawing

    ASSEMBLY DRAWING Part Description Qty. Bracket Screws Head Assembly Tank O-Ring Sump Tank 3/8” - 3/8” Compression Fittings 3/8” Brass Insert 3/8” Compression Sleeve 3/8” Compression Nut 3/8” Poly Tubing Faucet Fitting OMNI Filter Wrench Filter Cartridge (Model GAC1-SS Series A) DIBUJO DE LA UNIDAD ÉCLATÉ...