On the wiring diagram the following abbreviations are used:
BK
Black = max. speed
BU
Blue = medium speed
CN
Fast-on connector
F
Fuse, not supplied
GNYE Yellow/Green = earth
IL
Line switch
M
Motor
RD
Red = min. speed
WH White = common
1
To the control (accessory)
6
TEST RUN
Check that the unit is perfectly levelled and that the condensate drain pipe is not
obstructed (rubble deposits, etc.).
Check that the water connections (to the heat-exchanger and condensate drain)
are sealed.
Check that the electrical wiring is perfectly tight.
Be sure that air has been bled from the heat-exchanger.
Reassemble the cabinet (where existing).
Power-up the fan coil unit and check its working efficiency.
7
USE
To use the fan coil unit refer to the instructions of the control panel provided as an
accessory, normally accessed by lifting the side door.
Air outlet grills can be swivelled 180° to direct the flow into the room or towards
the wall on which the unit is mounted.
The grills and the side doors are snapped onto the cabinet. Before removing them
in order to change their position, cut the power off and wear protective gloves.
8
MAINTENANCE
WARNING: Maintenance must only be carried out by an assistance centre
authorised by the manufacturer or by qualified personnel.
For safety reasons before carrying out any maintenance or cleaning operation,
switch off the turning the speed selection switch to "Stop" and the power
supply switch to 0 (OFF).Be careful during any maintenance operation: you
could get injured by some metal parts therefore use protective gloves.
The fan coils FA do not require any particular maintenance operation: only the
periodical cleaning of the air filter should be carried out.
It is necessary to carry out a running in period of 100 hours in order to eliminate all
mechanical friction.
The starting up must be carried out at the maximum speed.
For good operation of the fan coils FA follow the instructions below:
- keep the air filter clean;
- do not pour liquids into the unit;
- do not introduce metal parts through the air outlet grill.
- keep the air inlet and outlet free at all times.
Each time the machine is turned on after being idle for a long period, ensure there
is no air in the heat exchanger.
Before using the unit for air conditions, check that:
- condensate drainage is performed correctly:
- the heat-exchanger fins are not obstructed by deposits of dirt. If necessary clean
the unit with low pressure compressed air or steam without damaging the fins.
9
CLEANING
WARNING: The filter must only be cleaned by an assistance centre
authorised by the manufacturer or by qualified personnel.
For safety reasons before carrying out any maintenance or cleaning operation
switch off the unit turning the speed selection switch to "Stop" and the power
supply switch to 0 (OFF).
Clean the filter at least once a month and in any case before using the unit (before
the heating or the air conditioning season).
For cleaning the air filter proceed as follows:
- remove the air filter as shown in figure 6 page 19;
- reassemble the filter after having dried it up.
It is recommended to replace the air filter yearly, and to use original spare parts.
The fan coil model is reported on the nameplate located on the internal side panel of
the unit.
To clean the unit cabinet proceed as follows:
- use a soft cloth;
- do not pour any liquid on the unit, as this could cause electrical shocks and damage
the components inside it;
- do not use any aggressive chemical solvents; do not use very hot water to clean
the air outlet grill.
È severamente vietata la riproduzione anche parziale di questo manuale / All copying, even partial, of this manual is strictly forbidden
10

TROUBLESHOOTING

If the unit does not work properly first check the points reported in the table below
before requesting service. If the problem cannot be solved contact your dealer or
service centre.
Problems
Cause
The unit does not run at all
1 Power failure
2 Leakage breaker tripped
3 The switch is on STOP
position
Poor cooling or heating per-
1 Dirty or clogged air filter
formance
2 Obstacle near the air inlet or
outlet
3 Air
exchanger
4 Doors and windows are open
5 The unit is running at low
speed
The unit leaks
1 The unit is not levelled
2 Drip tray is clogged
5
Solution
1 Restore power
2 Contact service centre
3 Turn on the unit selecting "I"
1 Clean air filter
2 Remove the obstacle
inside
the
heat
3 Contact the installer
4 Close doors and windows
5 Select medium or high fan
speed
1 Contact the installer
2 Contact the installer