Noise/Vibration Information
Measured sound values determined according
to 2000/14/EC (1.60 m height, 1 m distance
away).
Typically the A-weighted noise levels of the
product are: Sound pressure level 79 dB(A);
sound power level 93 dB(A). Uncertainty
K =1 dB.
Vibration total values (triax vector sum) deter-
mined according to EN 60335:
Vibration emission value a
Uncertainty K =1.5 m/s
Declaration of Conformity
We declare under our sole responsibility that
the product described under "Technical data" is
in conformity with the following standards or
standardization documents: EN 60335 accord-
ing to the provisions of the directives
2004/108/EC, 98/37/EC (until 28 Dec 2009),
2006/42/EC (from 29 Dec 2009), 2000/14/EC.
2000/14/EC: Guaranteed sound power level
94 dB(A). Conformity assessment procedure
according to Annex VI.
Equipment category: 32
Notified body:
SRL, Sudbury, England, Nr. 1088
Technical file at:
Bosch Lawn and Garden Ltd., PT-LG/EAE,
Stowmarket, Suffolk IP14 1EY, England
Dr. Egbert Schneider
Senior Vice President
Engineering
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
09.11.2009
Bosch Power Tools
2
<2.5 m/s
,
h
2
.
Dr. Eckerhard Strötgen
Head of Product
Certification
Assembly
For Your Safety
Warning! Switch off, remove plug from
mains before adjusting, cleaning or if cable
is cut, damaged or entangled.
The blades continue to rotate for a few sec-
onds after the machine is switched off.
Caution – do not touch the rotating blade.
Electrical Safety
Your machine is double insulated for safety and
requires no earth connection. The operating
voltage is 230 V AC, 50 Hz (for non-EU countries
220 V, 240 V as applicable). Only use approved
extension cables. Contact your Bosch Service
Centre for details.
Extension cords/leads should only be used if
they comply with H05VV-F, H05RN-F types or
IEC type design (60227 IEC 53, 60245 IEC 57).
If you want to use an extension cable when op-
erating your product, only the following cable di-
mensions should be used:
2
– 1.0 mm
: max. length 40 m
2
– 1.5 mm
: max. length 60 m
2
– 2.5 mm
: max. length 100 m
Note: If an extension cable is used it must be
earthed and connected through the plug to the
earth cable of your supply network in accord-
ance with prescribed safety regulations.
If in doubt contact a qualified electrician or the
nearest Bosch Service Centre.
WARNING! Inadequate extension cables
can be dangerous. Extension cable, plug
and socket must be of watertight construc-
tion and intended for outdoor use.
Cable connections should be kept dry and off
the ground.
It is recommended for increased electrical safe-
ty to use a Residual Current Device (RCD) with
a tripping current of not more than 30 mA. Al-
ways check your RCD every time you use it.
English | 19
F 016 L70 585 | (10.11.09)