TROUBLESHOOTING

Problem
Pump will not
1. Water level too low.
start or run.
2. Blown fuse or tripped circuit breaker.
3. Low line voltage.
4. Motor is defective.
5. Switch is defective.
6. Inlet screen clogged.
7. Switch is obstructed.
Possible Cause
10
16
Basin
cover
and
gasket
17
Corrective Action
1. Water must be at the appropriate level
to activate switch.
2. If blown, determine cause and then
either replace with properly sized fuse,
or reset breaker.
3. Contact an electrician.
4. Replace pump.
5. Replace switch.
6. Remove debris.
7. Remove obstruction to ensure free
motion of switch.