Zoeller 807 Instrucciones De Instalación

Zoeller 807 Instrucciones De Instalación

Ocultar thumbs Ver también para 807:
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Notice to Installer: Instructions must remain with installation.
Product information presented
here re fl
e
s t c
o c
d n
o i t i
s n
a
t t
m i
e
of publication. Consult factory
e r
a g
i d r
g n
d
c s i
e r
a p
c n
s e i
r o
n i
o c
s n
t s i
n e
e i c
. s
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover
nor the motor housing.
2. Carefully read the literature
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle or control box
must be installed in accordance with the governing codes. Never remove ground pin
from plug.
2. Make certain that the receptacle or control box is within reach of the pump's power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are too long
a safety hazard if the insulation were to become damaged or the connection end were
to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit breakers
of proper capacity. A separate branch circuit is recommended, sized according to the
governing electrical codes for the current shown on the pump name plate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked
for ground using a circuit analyzer which will indicate if the power, neutral and ground
electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. If pump is wired direct, de-energize the circuit at the
control box. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND
PIN. Wear insulated protective shoes and do not stand in water. Pumps equipped
with a grounded plug are designed to help protect against electrical shock. A properly
grounded receptacle or control box must be installed in accordance with governing
codes.
6. Installation and servicing of the pump's electrical circuits and hardware should only be
7. Installation and maintenance of this appliance is not intended for persons (including
children) with reduced physical, sensory or mental capabilities, or lack of experience
or knowledge, unless they have been given supervision or instruction concerning use
of the appliance by a person responsible for their safety.
8. Risk of electrical shock. Do not remove power supply cord and strain relief or connect
conduit directly to the pump. If the supply cable is damaged, it must be replaced by an
authorized Zoeller Representative.
9. Pump may contain oil which becomes pressurized and hot when operating. Allow 2-1/2
hours after disconnecting before attempting service.
10. Pump is not intended for potable water due to possible contamination by oil contained
in the pump.
11. Risk of electrical shock. These pumps have not been investigated for use in swimming
pools and marine areas.
DO NOT USE FOR PUMPING OILS, GASOLINE OR ANY PETROLEUM BY-PRODUCTS.
INSTALLATION INSTRUCTIONS
807 / 2702 / 2712
2722 / 2732 / 2741 / 2742
© Copyright 2020 Zoeller Co. All rights reserved.
These materials should be retained for future reference.
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the manual
look for one of the following signal words and be alert to
the potential for personal injury or property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
Warns of electrical shock hazards that CAN cause serious
personal injury, death or major property damage.
Identifies any terminal which is intended for connection
to an external conductor for protection against electrical
shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO WARRANTY ON PAGE 02.
®
- 1 -
ZT0218_ESc
Supersedes
50/60 Hz
Visit our web site:
zoellerpumps.com
P/N 094294
0420
0717
Tabla de contenido
loading

Resumen de contenidos para Zoeller 807

  • Página 1 11. Risk of electrical shock. These pumps have not been investigated for use in swimming pools and marine areas. REFER TO WARRANTY ON PAGE 02. DO NOT USE FOR PUMPING OILS, GASOLINE OR ANY PETROLEUM BY-PRODUCTS. P/N 094294 ® © Copyright 2020 Zoeller Co. All rights reserved. - 1 -...
  • Página 2 Model 807 maximum operating temperature must not exceed 54 °C (130 °F). not hang up on the pump apparatus or pit peculiarities and is secured so that Model 2702, 2722, 2732HF maximum operating temperature must not exceed the pump will shut off.
  • Página 3: General Maintenance

    Installation and checking of electrical circuits and hardware should be performed Every 5 years or 10,000 hours of operation: • Remove pump, inspect and service using a Zoeller rebuild kit. Pump is never to be lifted by power cord. • Flush and clean basin.
  • Página 4 10cm (4") OF GRAVEL SK3108 piping, valves, etc. Float hangers are available from Zoeller Company on All installations must comply with all applicable electrical and plumbing codes.
  • Página 5 WHITE 400 µF 90 µF 2732HH BLACK WHITE 250 VAC 250 VAC 70 µ 2742 WHITE 250 VAC 300 VAC START MAIN MOTOR THERMAL PROTECTOR MOTOR EA0120 EA0115 ® © Copyright 2020 Zoeller Co. All rights reserved. - 5 -...
  • Página 6 BLUE (WHITE) BLUE (WHITE) (GREEN) GREEN/YELLOW drill 3 mm (1/8") hole in Control Back Plate Pump For Mounting Breaker Power Cord Bracket. These are the original installation instructions. ® © Copyright 2020 Zoeller Co. All rights reserved. - 6 -...
  • Página 7: Lista De Verificación Para Antes De Instalar - Todas Las Instalaciones

    LLEVAR A CABO CUALQUIER TRABAJO CON LA BOMBA. está dañado, debe ser reemplazado por un representante autorizado de Zoeller. MANTENGA TODAS LAS CALCOMANÍAS DE SEGURIDAD. La bomba podría contener aceite, el cual se presuriza y calienta durante la operación.
  • Página 8: Garantía Limitada

    45 cm (18”) o mayor. Company. La temperatura de funcionamiento máxima en el Modelo 807 no debe Orificio de ventilación.Es necesario que todas las bombas de sumidero sobrepasar los 54 ºC (130 ºF).La temperatura de funcionamiento máxima en sumergible, efluentes y aguas negras capaces de manejar varias los Modelos 2702, 2722, 2732HF no debe sobrepasar los 40 ºC (104 ºF).
  • Página 9: Mantenimiento General

    Consulte con la fábrica en caso de que la lista de verificación anterior no revele el problema.No intente reparar ni desarmar la bomba usted mismo.El servicio debe ser realizado únicamente por un representante autorizado de Zoeller Company. © Copyright 2020 Zoeller® Co. Todos los derechos reservados.
  • Página 10: Instalación Recomendada Para Todas Las Aplicaciones

    Los colgadores de flotador están disponibles en Zoeller Company en la hoja de catálogo FM0526 o pueden Todas las instalaciones deben cumplir con todos los códigos de fabricarse con tubería estándar y accesorios.
  • Página 11 WHITE 400 µF 90 µF 2732HH BLACK WHITE 250 VAC 250 VAC 70 µ 2742 WHITE 250 VAC 300 VAC START MAIN MOTOR THERMAL PROTECTOR MOTOR EA0120 EA0115 © Copyright 2020 Zoeller® Co. Todos los derechos reservados. - 11 -...
  • Página 12 (WHITE) BLUE (WHITE) (GREEN) GREEN/YELLOW drill 3 mm (1/8") hole in Control Back Plate Pump For Mounting Breaker Power Cord Bracket. Estas son las instrucciones de instalación originales. © Copyright 2020 Zoeller® Co. Todos los derechos reservados. - 12 -...

Este manual también es adecuado para:

270227122722273227412742

Tabla de contenido