Zoeller 2701 Instrucciones De Instalación
Ocultar thumbs Ver también para 2701:
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Notice to Installer: Instructions must remain with installation.
Product information presented
here re fl
e
s t c
o c
d n
o i t i
s n
a
t t
m i
e
of publication. Consult factory
e r
a g
i d r
g n
d
c s i
e r
a p
c n
s e i
r o
n i
o c
s n
t s i
n e
e i c
. s
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover
nor the motor housing.
2. Carefully read the literature
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle or control box
must be installed in accordance with the governing codes. Never remove ground pin
from plug.
2. Make certain that the receptacle or control box is within reach of the pump's power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are too long
a safety hazard if the insulation were to become damaged or the connection end were
to fall into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit breakers
of proper capacity. A separate branch circuit is recommended, sized according to the
governing electrical codes for the current shown on the pump name plate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked
for ground using a circuit analyzer which will indicate if the power, neutral and ground
electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. If pump is wired direct, de-energize the circuit at the
control box. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND
PIN. Wear insulated protective shoes and do not stand in water. Pumps equipped
with a grounded plug are designed to help protect against electrical shock. A properly
grounded receptacle or control box must be installed in accordance with governing
codes.
6. Installation and servicing of the pump's electrical circuits and hardware should only be
7. Installation and maintenance of this appliance is not intended for persons (including
children) with reduced physical, sensory or mental capabilities, or lack of experience
or knowledge, unless they have been given supervision or instruction concerning use
of the appliance by a person responsible for their safety.
8. Risk of electrical shock. Do not remove power supply cord and strain relief or connect
conduit directly to the pump. If the supply cable is damaged, it must be replaced by an
authorized Zoeller Representative.
9. Pump may contain oil which becomes pressurized and hot when operating. Allow 2-1/2
hours after disconnecting before attempting service.
10. Pump is not intended for potable water due to possible contamination by oil contained
in the pump.
11. Risk of electrical shock. These pumps have not been investigated for use in swimming
pools and marine areas.
DO NOT USE FOR PUMPING OILS, GASOLINE OR ANY PETROLEUM BY-PRODUCTS.
INSTALLATION INSTRUCTIONS
© Copyright 2020 Zoeller Co. All rights reserved.
2701
These materials should be retained for future reference.
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the manual
look for one of the following signal words and be alert to
the potential for personal injury or property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
Warns of electrical shock hazards that CAN cause serious
personal injury, death or major property damage.
Identifies any terminal which is intended for connection
to an external conductor for protection against electrical
shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO WARRANTY ON PAGE 02.
®
- 1 -
ZT0300_EFSa
Supersedes
60 Hz
Visit our web site:
zoellerpumps.com
P/N 094398
0420
0218
Tabla de contenido
loading

Resumen de contenidos para Zoeller 2701

  • Página 1 11. Risk of electrical shock. These pumps have not been investigated for use in swimming pools and marine areas. REFER TO WARRANTY ON PAGE 02. DO NOT USE FOR PUMPING OILS, GASOLINE OR ANY PETROLEUM BY-PRODUCTS. P/N 094398 ® © Copyright 2020 Zoeller Co. All rights reserved. - 1 -...
  • Página 2 Model 807 maximum operating temperature must not exceed 54 °C (130 °F). not hang up on the pump apparatus or pit peculiarities and is secured so that Model 2701,2702, 2722, 2732HF maximum operating temperature must not the pump will shut off. It is recommended to use rigid piping and fittings and exceed 40 °C (104 °F).
  • Página 3: General Maintenance

    Installation and checking of electrical circuits and hardware should be performed Every 5 years or 10,000 hours of operation: • Remove pump, inspect and service using a Zoeller rebuild kit. Pump is never to be lifted by power cord. • Flush and clean basin.
  • Página 4 10cm (4") OF GRAVEL SK3108 piping, valves, etc. Float hangers are available from Zoeller Company on All installations must comply with all applicable electrical and plumbing codes.
  • Página 5: Instructions De Sécurité

    PAS enlever les bouchons test du la pompe. 2. Il faut lire attentivement tous les documents consulter ultérieurement. 3. Zoeller déconseille l'utilisation de pompes broyeuses pour toute partie du système septique. Instructions de sécurité VOIR PLUS BAS POUR LA AVERTISSEMENT LISTE DES AVERTISSEMENTS POUR ÉVITER TOUTE BLESSURE SÉRIEUSE OU FATALE OU DOMMAGE MATÉRIEL...
  • Página 6: Garantie Limitée

    ATTENTION VOIR PLUS BAS POUR LA LISTE DES MISES EN GARDE faites que par un centre de réparation agréé par Zoeller Pump Company. L’installateur est responsable de l’installation des interrupteurs à niveau variable et il La température de fonctionnement maximale d’une pompe standard ne peut pas être pas à...
  • Página 7: Entretien Général

    Inspecter la ligne. Si les vérifications ci-dessus ne résolvent le problème, consulter l’usine. Ne pas essayer de réparer ou de démonter la pompe. Toutes les réparations doivent être faites par un centre de réparation agréé par Zoeller. ®...
  • Página 8 (2) Installer un Unicheck (raccord / clapet de sécurité combiné) de Zoeller approprié, de préférence juste au-dessus du puits pour permettre la dépose de la pompe (6) Utiliser un tuyau de évacuation de pleines dimensions.
  • Página 9: Lista De Verificación Para Antes De Instalar - Todas Las Instalaciones

    LLEVAR A CABO CUALQUIER TRABAJO CON LA BOMBA. está dañado, debe ser reemplazado por un representante autorizado de Zoeller. MANTENGA TODAS LAS CALCOMANÍAS DE SEGURIDAD. La bomba podría contener aceite, el cual se presuriza y calienta durante la operación.
  • Página 10: Garantía Limitada

    (ON/OFF) del flotador.La reparación y el servicio pueda apagarse.Se recomienda usar tuberías y conectores rígidos y que la deben ser realizados únicamente por un representante autorizado de Zoeller cavidad sea de un diámetro de 45 cm (18”) o mayor.
  • Página 11: Mantenimiento General

    Consulte con la fábrica en caso de que la lista de verificación anterior no revele el problema.No intente reparar ni desarmar la bomba usted mismo.El servicio debe ser realizado únicamente por un representante autorizado de Zoeller Company. © Copyright 2020 Zoeller® Co. Todos los derechos reservados.
  • Página 12: Instalación Recomendada Para Todas Las Aplicaciones

    Los colgadores de flotador están disponibles en Zoeller Company en la hoja de catálogo FM0526 o pueden Todas las instalaciones deben cumplir con todos los códigos de fabricarse con tubería estándar y accesorios.

Tabla de contenido