ATTACHING FAN TO MOUNT
Use the supplied hardware to attach fan to the mount.
The 3/8" bolt installs through the center hole of the
motor yoke bracket. The 1/4" bolt fastens through the
slot feature. Adjust fan to desired angle and securely
tighten all nuts. (See Figure 2)
NOTE: Bolts should be installed with a washer
on either side of the motor yoke bracket.
Figure 2
1/4" bolt
3/8" bolt
Fan mount designs may vary. Fan must always be
attached to the mount through center hole of the motor
yoke bracket using 3/8" bolt.
CAUTION! Nuts may loosen over time. It is
important to check and tighten fasteners
frequently.
CAUTION! Inspect fan components and
fasteners frequently for corrosion. Replace any
corroded fasteners or parts.
SAFETY CABLE
A secondary support cable (not included) should be
installed anytime the fan is mounted overhead for
additional safety. (See Figure 3)
NOTE: Safety cable must go around the large
diameter wires of front and rear guards.
Other end of safety cable must be securely fastened
to a building joist, truss or beam near the fan. Take
up all necessary slack in the cable. (See Figure 3)
Figure 3
PAGE 3 OF 12
INSTRUCTIONS CONTINUED
Washer
Nut
Motor Yoke
Bracket
REMOVING MOTOR DRAIN PLUGS
After installing the fan, remove the motor drain plug
located at the lowest point of the motor.
NOTE: Failure to remove the drain plug may
allow condensation to build up inside the
motor, reducing motor life, and will void the
warranty. Do not remove drain plugs on the top
side of the motor.
Drain plug locations and quantity may vary by motor
design. (See Figure 4)
Figure 4
Pedestal
Mounted Fan
Drain Plug
Removal
0821 IH-7096