FRAGMA
No.
MEANING
P 01
Automatic reclosure
P 02
Pause time
P 03
Opening mode
P 04
Pre-flash
PCS
Immediate closure
P 06
STPA input
P 07
AUX output flash
P 08
Check photocells
P 09
Start closing slow-down
P 10
Start opening slow-down
P 11
Maximum opening speed
P 12
Maximum closing speed
P 13
Opening slow-down speed
P 14
Closing slow-down speed
P 15
Torque (Force)
P 16
Not used
P 17
Brake intensity on closing
P 16
Mode only open / only closed
P 19
Not used
P 20
Not used
P 21
2CAN terminal activation time
P 22
Not used
P 23
Not used
P 24
Self start (5 = max soft)
P 25
Slow-down ramp (8= steep)
P 26
Travel limit
P 27
Flash light on during battery operation
P 28
Not used
P 29
Not used
P 30
Mode MASTER/SLAVE
6.
EDITING PARAMETERs
Initially the current parameter value is displayed but not flashing. Press the "UP ARROW" or "DOWN ARROW" buttons to edit the value, the display starts
flashing. Press "OK" to confirm the value. The new value is saved in the memory and the display stops flashing.
Press the "ESC" button to return to the parameters list.
REsTORE DEFAULT vALUEs
Press either the "UP ARROW" or "DOWN ARROW" button until the "DEF" item appears and then press "OK" to restore the default values given in the table.
A line of dots "oooo" appears on the display to confirm the operation. Press "ESC" to return to the main menu.
CYCLEs (CNT)
Press either the "UP ARROW" or "DOWN ARROW" button until the "CNT" item appears and then press "OK" to display the number of opening cycles com-
pleted by the motors. Two counters are available, one total counter and one partial counter. Press either the "UP ARROW" or "DOWN ARROW" button to
display the items. Press "ESC" to return to the main menu.
DIsPLAY
Axxx
xxxx
Pxxx
xxxx
Example:
A000-0010 the total counter has counted 10 cycles.
P021-2034 the partial counter has counted 212034 cycles.
Note: the counter values are saved every 16 cycles.
EN
MEANING
Represents the most significant part of the total counter value
Represents the least significant part of the total counter value
Represents the most significant part of the partial counter value. Press and hold [OK] to reset it
Represents the least significant part of the partial counter value. Press and hold [OK] to reset it
VALUES
on/off
2 - 600 sec
1 = condominium
2 = open/stop/close
3 = open/close
on/off
on/off
1 = photocell int.
2 = normal edge
3 = resistive edge
1 = no flash
2 = flash - off
3 = flash - on
on/off
0 - 100 %
0 - 100 %
50 - 100 %
50 - 100 %
20 - 75 %
20 - 75 %
40 - 100 %
/
0-10
0 = disabled
1 = APCH only open,
PED only closed
/
/
1 - 60 sec
/
/
1 - 5
1 - 8
Off - Op - Cl - OpCl
on/off
/
/
0 = disabled
1 = master
2 = slave
DEFAULT
on
60 sec
1
on
off
1
off
off
30%
70%
100%
100%
50%
50%
60%
/
5
0
/
/
5 sec
/
/
3
7
off
off
/
/
0
23