PERATING ENVIRONMENT FOR SENSORS AND EXPANDERS
EAGLE sensor and expander devices are designed to operate in normal environmental
conditions as described in standard IEC60950:
temporary conductivity caused by condensation that is to be expected)
Note: For temperatures over 70°C, access to the sensor should be restricted, either to
authorized personnel, or mechanically or by a warning of the "hot surface" type.
2.4.
H
AZARDOUS ENVIRONMENTS FOR SENSORS AND EXPANDER
Sensors and expander are designed for surface industry, category 1G for gas (zone 0) and
underground category 1M.
Standards applied:
Explosive atmospheres - Part 0: General requirements
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Explosive atmospheres - Part 0: General requirements
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Special condition for a safe use:
cell in a safe area
shocks.
expanders in all hazardous areas to eliminate static electricity resulting from this
operation.
Altitude up to 2,000 m [6,500 ft]
Temperature ranging from -20°C to +85°C [-4°F/+185°F])
Pollution rating 2 (only non-conductive pollution occurs, except for occasional
< 95% non-condensing relative humidity
Indoor & outdoor use
I M1 Ex ia I Ma
II 1 G Ex ia IIC T3 Ga -20°C< Ta < +85°C (-4°F ≤ Tamb ≤+185°F)
LCIE 14 ATEX 3058 X
IECEx LCIE 14.0048 X
EN60079-0
2012 edition
EN60079-11
2012 edition
IEC 60079-0 : 2011 Edition: 6.0
IEC 60079-11 : 2011 Edition: 6.0
-20°C ≤ Tamb ≤ +85°C
WARNING – USE ONLY SAFT LS33600 BATTERY. Only replace the primary
The equipment must be installed so that it is protected against mechanical
A damp cloth should be used when installing or taking off the sensors and
Brand of ACOEM