posing of waste. For more information on the treatment,
re-use and recycling of this product, please contact your
local authority, domestic waste collection service or the
shop where the appliance was purchased.

INSTALLATION INSTRUCTIONS

• Assembly and electrical connections must be
carried out by specialised personnel.
• Wear protective gloves before proceeding with
the installation.
• Electric Connection:
Note! Verify the data label placed inside the appliance:
- If the symbol
appears on the plate, it means that
no earth connection must be made on the appliance,
therefore follow the instructions concerning insulation
class II.
- If the symbol
DOES NOT appear on the plate, follow
the instructions concerning insulation class I.
Insulation class II
- The appliance has been manufactured as a class II,
therefore no earth cable is necessary. The plug must be
easily accessible after the installation of the appliance.
If the appliance is equipped with power cord without
plug, a suitably dimensioned omnipolar switch with 3
mm minimum opening between contacts must be fitted
between the appliance and the electricity supply in
compliance with the load and current regulations.
- The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral.
Insulation class I
This is a class I, appliance and must therefore be con-
nected to an effiecient earthing system.
- The appliance must be connected to the electricity
supply as follows:
BROWN = L line
BLUE = N neutral
YELLOW/GREEN =
earth.
The neutral wire must be connected to the terminal with
the N symbol while the YELLOW/GREEN, wire must be
connected to the terminal by the earth symbol
When connecting the appliance to the electricity supply,
make sure that the mains socket has an earth connection.
After fitting the ducted cooker hood, make sure that the
electrical plug is in a position where it can be accessed
easily. If the appliance is connected directly to the electri-
city supply, an omnipolar switch with a minimum contact
opening of 3 mm must be placed in between the two; its
size must be suitable for the load required and it must
comply with current legislation.
• If the hob is electric, gas, or induction, the minimum di-
stance between the same and the lower part of the hood
must be at least 65 cm. If a connection tube composed of
two parts is used, the upper part must be placed outside
the lower part. Do not connect the cooker hood exhaust
to the same conductor used to circulate hot air or for
evacuating fumes from other appliances generated by
other than an electrical source. Before proceeding with
the assembly operations, remove the anti-grease filter(s)
(Fig.5) so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which
has the same diameter as the air exhaust outlet hole. If a
pipe with a smaller diameter is used, the efficiency of the
product may be reduced and its operation may become
noisier.
• If your appliance has been designed for use in habita-
tions supplied with acentralised suction device perform
the following operations:
- The switch controls opening and closure of a valve using
a thermoelectical device. By placing the switch in the ON
position, after a minute, the valve opens rotating 90°
allowing suction of the stale air. By placing the switch in
the OFF position, the valve closes after 100 seconds.
• Fixing to the wall:
Drill the holes A respecting the distances indicated
(Fig.2). Fix the appliance to the wall and align it in ho-
rizontal position to the wall units. When the appliance
has been adjusted, definitely fix the hood using the
screws A (Fig.4).
For the various installations use screws and screw an-
chors suited to the type of wall (e.g. reinforced concrete,
plasterboard, etc.).
If the screws and screw anchors are provided with the
product, check that they are suitable for the type of wall
on which the hood is to be fixed.
• Fixing the decorative telescopic flue:
Arrange the electrical power supply within the dimen-
sions of the decorative flue. If your appliance is to be
installed in the ducting version or in the version with
external motor, prepare the air exhaust opening. Adjust
the width of the support bracket of the upper flue (Fig.3).
Then fix it to the ceiling using the screws A (Fig.3) in such
a way that it is in line with your hood and respecting the
distance from the ceiling indicated in Fig.2. Connect the
flange C to the air exhaust hole using a connection pipe
(Fig.4). Insert the upper flue into the lower flue and rest
above the frame. Extract the upper flue up to the bracket
and fix it with the screws B (Fig.3). To transform the hood
from a ducting version into a filtering version, ask your
dealer for the charcoal filters and follow the installation
instructions.
.
• Filtering version:
Install the hood and the two flues as described in the
paragraph for installation of the hood in ducting version.
To assemble the filtering flue refer to the instructions
contained in the kit. If the kit is not provided, order it from
your dealer as accessory.
The filters must be applied to the suction unit positioned
inside the hood. They must be centred by turning them
90 degrees until the stop catch is tripped (Fig.6).

USE AND MAINTENANCE

• We recommend that the cooker hood is switched on
before any food is cooked. We also recommend that the
appliance is left running for 15 minutes after the food is
cooked, in order to thoroughly eliminate all contaminated
air. The effective performance of the cooker hood depen-
ds on constant maintenance; the anti-grease filter and
the active carbon filter both require special attention.
• The anti-grease filter is responsible retaining the
grease particles suspended in the air, therefore it is
subject to clogging with variable frequency according
to the use of the appliance.
- 13 -