Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SYMBOLOGY
Volts
Direct Current
Alternating Current
Double Insulated
CAUTION
- Do Not Stare Into Beam
UL Listing for Canada and U.S.
C
US
SPECIFICATIONS
Cat. No. ..................................................... 2360-20
AC Input Volts ....................................................120
DC Input Volts......................................................18
Max AC Input Amps ...............................................1
Max DC Input Amps............................................2.5
Hertz ....................................................................60
GROUNDING
WARNING
risk of electric shock. Check with a qualified
electrician if you are in doubt as to whether the
outlet is properly grounded. Do not modify the
plug provided with the tool. Never remove the
grounding prong from the plug. Do not use the
tool if the cord or plug is damaged. If damaged,
have it repaired by a MILWAUKEE service facil-
ity before use. If the plug will not fit the outlet,
have a proper outlet installed by a qualified
electrician.
Grounded Tools (Three-Prong Plugs)
Tools marked "Grounding Required" have a three
wire cord and three prong grounding plug. The plug
must be connected to a properly grounded outlet
(See Figure A). If the tool should electrically mal-
function or break down, grounding provides a low
resistance path to carry electricity away from the
user, reducing the risk of electric shock.
The grounding prong in the plug is connected through
the green wire inside the cord to the grounding
system in the tool. The green wire in the cord must
be the only wire connected to the tool's grounding
system and must never be attached to an electrically
"live" terminal.
Your tool must be plugged into an appro-
priate outlet, properly installed and
grounded in accordance with all codes
and ordinances. The plug and outlet
should look like those in Figure A.
Double Insulated Tools (Two-Prong Plugs)
Tools marked "Double Insulated" do not require
grounding. They have a special double insulation
system which satisfies OSHA requirements and
Laser Light
Improperly connect-
ing the grounding
wire can result in the
Fig. A
complies with the applicable standards
of Underwriters Laboratories, Inc., the
Canadian Standard Association and
the National Electrical Code. Double
Insulated tools may be used in either
of the 120 volt outlets shown in Figures
B and C.

EXTENSION CORDS

Grounded tools require a three wire extension
cord. Double insulated tools can use either a two
or three wire extension cord. As the distance from
the supply outlet increases, you must use a heavier
gauge extension cord. Using extension cords with
inadequately sized wire causes a serious drop in
voltage, resulting in loss of power and possible tool
damage. Refer to the table shown to determine the
required minimum wire size.
The smaller the gauge number of the wire, the greater
the capacity of the cord. For example, a 14 gauge
cord can carry a higher current than a 16 gauge cord.
When using more than one extension cord to make
up the total length, be sure each cord contains at
least the minimum wire size required. If you are using
one extension cord for more than one tool, add the
nameplate amperes and use the sum to determine
the required minimum wire size.
Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be sure
it is marked with the suffix "W-A" ("W" in Canada)
to indicate that it is acceptable for outdoor use.
• Be sure your extension cord is properly wired
and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a
qualified person before using it.
• Protect your extension cords from sharp objects,
excessive heat and damp or wet areas.
Recommended Minimum Wire Gauge
For Extension Cords*
Nameplate Amps
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 16.0
16.1 - 20.0
* Based on limiting the line voltage drop to five volts at 150%
of the rated amperes.
READ AND SAVE ALL INSTRUCTIONS
FOR FUTURE USE.
ASSEMBLY
WARNING
specific charging instructions, read the opera-
tor's manual supplied with your charger and
battery.
Inserting/Removing the Battery
Insert the battery pack by sliding battery pack into
the body of the tool. Insert the battery pack until the
battery latches lock.
To remove the battery pack, press in both battery
latches and slide the battery pack off of the tool.
3
Fig. B Fig. C
Extension Cord Length
25'
50'
75'
100'
18
18
18
18
18
18
18
16
18
18
16
14
18
16
14
12
16
14
12
10
14
12
10
--
12
10
--
--
Recharge only with
the charger specified
for the battery. For
150'
16
14
12
12
--
--
--
Tabla de contenido
loading

Tabla de contenido