do not cover the appliance
•
Never rest objects of any kind on the air conditioner.
•
Never obstruct the air intake or outlet grilles.
CLEANING
Before cleaning or maintenance, turn the appliance off by using
the
button, then unplug from the outlet.
CLEANING THE CABINET
You should clean the appliance with a slightly damp cloth then
dry with a dry cloth. For safety reasons, never wash the air con-
ditioner with water.
Precautions
Never use petrol, alcohol or solvents to clean the appliance. Nev-
er spray insecticide liquids or similar.
CLEANING THE BIO SILVER AIR FILTER (If fitted)
If the filter is dirty, air circulation is compromised and the effi-
ciency of the appliance decreases.
It is therefore good practice to clean the filter at regular inter-
vals. The frequency depends on the duration and conditions of
operation. If the unit is used constantly or systematically, you are
recommended to clean the filter once a week.
The filter is housed in the intake grille.
Remove the grille to access the filter. To clean the filter, it will
need to be extracted as shown in fig. 9.
9
Use a vacuum cleaner to remove any dust deposited on the filter.
If it is very dirty, submerge it into warm water and rinse it several
times. The water temperature must be kept below 104° F (40°C).
After washing the filter, allow it to dry completely before
repositioning it.
The BioSilver filter helps capture dust and pollen and helps re-
duce the growth of bacteria and mold on the filter.
CHECKS AT THE START OF THE SEASON
Make sure the power cable and socket are in perfect condition
and make sure the grounding system is sufficient. Comply strict-
ly with the installation standards.
END OF SEASON OPERATIONS
To drain all water from the circuit, remove the cap A11 from the
drainage on the back of the appliance and allow the water to
drain out into a basin (fig. 10).
To facilitate this operation, at the start of the season, it's possible
to apply the water drain hose with cap B8.
In order to properly storage the appliance at the end of the sea-
son, we suggest you cover it with the supplied end of season
dust cover B10 and you put the accessories in the relevant
end of season accessories bag B11.
10
When the appliance is empty, replace the cap.
Clean the filter and dry thoroughly before putting back. Unit
should be stored in large, well ventilated area.
TECHNICAL SPECIFICATIONS
Power supply voltage
Max. absorbed power during air conditioning
Refrigerant
Cooling capacity
14
see rating label
"
"
"