Cebora SOUND PC 9060/T Manual De Instrucciones página 11

Equipo de corte en plasma
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
way in case of error. The table below shows how the
number displayed corresponds to the event detected and
what corrective measures to undertake.
COD. ERROR
0-49 Hardware crash.
service center.
50
Torch guard R
51
Torch not suitable for Check the type of torch
this machine.
52
The torch start
command was pressed shut the machine off
while the machine was and turn it back on.
turned on.
pressing the torch trigger
53
The torch start
command was pressed shut the machine off
while the LEDS G and and turn it back on.
L were off.
54
Short-circuit between Replace electrode and
the electrode and
nozzle.
55
Worn out electrode
6.2
PRECAUTIONS AFTER REPAIRS.
After making repairs, take care to organize the wiring so that
there is secure insulation between the primary and sec-
ondary sides of the machine. In particular, make sure that the
casing 65 is mounted (see exploded drawing). Do not allow
the wires to come into contact with moving parts or those
that heat up during operation. Reassemble all clamps as
they were on the original machine, to prevent a connection
from occurring between the primary and secondary circuits
should a wire accidentally break or be disconnected.
Also mount the screws with geared washers as on the
original machine.
SOLUTION
Contact the technical
Insert the missing guard
(see1.1)
Open the start command,
Wait 5 sec. before
Open the start command,
Wait 5 sec. before pres-
sing the torch trigger
nozzle.
Replace electrode and
nozzle.
11
Tabla de contenido
loading

Tabla de contenido