Do not twist the hydraulic hoses when reconnecting the hoses. Twisted hoses may fail
prematurely.
6. Loosen the connection between #6 M/M el-
bow and #6 M/F elbow on fl ow restrictor as-
sembly (FIG. 4-1A). Connect #6 M/F elbow
to port on pump (FIG. 4-1A). Next, position
the assembly to align tee with hydraulic
hoses (FIG. 4-1A). Then, connect hydraulic
hoses to tee.
©
MAXON Lift Corp. 2021
LIFT CORPORATION Sht. 4 of 12 DSG#
CAUTION
HYDRAULIC HOSE
(2 PLACES)
TEE
ELBOW, #6 M/F
(P/N 906939-01)
PUMP PORT
CONNECTION
CONNECTING FLOW RESTRICTOR KIT
M-21-11
Rev. - Date: 06/25/21
ELBOW, #6 M/M
(P/N 906722-01)
FIG. 4-1A