Sears Kenmore 139.34172410 Manual De Uso Y Cuidado página 6

Parrilla a gas de propane liquido
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Hold
coupling
nut and regulator
as shown
for
proper
connection
to LP tank
valve.
Leak Testing Valves, Hose and Regulator
1. Turn all grill control knobs to OFF.
2. Be sure regulator
is tightly connected to LP tank.
3. Completely
open LP tank valve by turning OPD hand wheel
counterclockwise.
If you hear a rushing sound, turn gas off
immediately.
There is a major leak at the connection.
Correct before proceeding
by calling Sears for
replacement
parts at 1-800-4-MY-HOME®.
6. Turn the coupling nut clockwise and tighten to a full stop.
The regulator
will seal on the back-check
feature in the LP
tank valve, resulting in some resistance. An additional
one-half
to three-quarters
turn is required to complete
the connection.
Tighten by hand only - do not use tools.
4. Brush soapy solution onto areas where bubbles are shown
in picture below:
A
Never
remove
threaded
orifice
at end of valve.
NOTE:
If you cannot complete
the connection, disconnect
regulator
and repeat steps 5 and 6. If you are still unable to complete
the
connection, do not use this regulator!
Call 1-800-482-0131
for assistance.
° Do not insert any tool or foreign object into the valve
outlet or safety relief valve. You may damage the valve
and cause a leak. Leaking propane may result in
explosion, fire, severe personal injury, or death.
° Outdoor gas appliance is not intended to be installed
in or on a boat.
° Outdoor gas appliance is not intended to be installed
in or on an RV.
° Never attempt to attach this grill to the self-contained
LP gas system of a camper trailer or motor home.
° Do not use grill until leak-tested.
° If a leak is detected at any time, STOP and call the
fire department.
° If you cannot stop a gas leak, immediately
close
LPcylinder valve and call LP gas supplier or your fire
department!
5. If "growing"
bubbles appear, there is a leak. Close LP tank
valve immediately
and retighten connections.
If leaks
cannot be stopped do not try to repair. Call Sears for
replacement
parts at 1-800-4-MY-HOME®.
6. Always close LP tank valve after performing
leak test by
turning hand wheel clockwise.
Tabla de contenido
loading

Tabla de contenido