28 | FSA 740 Edition |
8.1.3
Specification measurement leads
Designation
Connecting cable B+/B–
Clip-on trigger
Primary connecting cable
(UNI 4)
Multi measurement lead CH1
Multi measurement lead CH2
Measurement lead
with voltage divider
Accessory set with:
Test prods
Pick-off clips
Adapter connectors
Current probe 1000 A
Current probe 30 A
Accessory set with test
prods, test clips
Secondary measuring trans-
ducer
Temperature sensor
Connection at secondary input sensor
1)
1.6 Vpeak ±30 % at 100 mA current change within 200 ns with connection at input clip-on sensor (L/C approx. 136 µH/5 nF)
2)
For voltages >60 V, U[V] x t[ms] ≤ 3200 V/ms applies, e.g. a voltage of 200 V can be applied no longer than 16 μs. The maximum voltage
3)
decreases with frequencies >1 MHz at 20 dB/decade, e.g. sinus 1 MHz maximum peak = 200 V / sinus 10 MHz maximum peak = 20 V
8.1.4
Oscilloscope
R
Trigger system
$
Free run (non-triggered run for ≥ 1 s)
$
Auto (curve output even without trigger)
$
Auto level (as Auto, mid-signal trigger threshold)
$
Normal (manual trigger threshold, curve output
only with trigger event)
$
Single sequence
R
Trigger edge
$
Edge (pos. / neg. on signal)
R
Trigger sources
$
Engine (trigger on cylinder 1 ... 12 with clip-on
trigger, term. 1, KV sensor)
$
External trigger via term. 1_1 wire or clip-on trig-
ger
$
Multi measurement lead CH1 / CH2
R
Pre-trigger component
$
0 to 100 %, adjustable with mouse
R
Recording modes
$
MaxMin (Peak/Glitchdetect)
$
Interference pulses
$
Sample (equidistant sampling)
R
Storage and curve output modes
$
Roll mode (single point output) with complete
storage of signals for X-sweeps ≥ 1 s
$
Legend mode (curve output) with complete stor-
age of signals for X-sweeps ≥ 1 ms
$
Normal mode with storage of last 50 curves
displayed for X-sweeps < 1 ms
1 689 989 089
|
2018-03-24
Order number
Measuring
category
1 684 460 195
CAT 0
1 687 224 957
CAT 0
1 684 462 563
CAT 0
1 684 460 258
CAT 0
1 684 460 259
1 687 224 300
CAT 0
1 687 016 118
1 684 485 434/ ... 435
CAT 3
1 684 480 403/ ... 404
CAT 2
1 684 480 125
CAT 2
1 687 224 968
CAT 0
1 687 224 969
CAT 0
1 687 010 153
CAT 0
1 687 224 973
CAT 0
1 687 230 036
CAT 0
Max. measuring
Output sensitivity
voltage
sensor lead
60 VDC, 30 VAC,
300 VACpeak
30 kV ACpeak
2)
32 VDC, 30 VAC,
3)
320 VACpeak
60 VDC, 30 VAC,
3)
42 VACpeak
60 VDC, 30 VAC,
25 V/V
300 VACpeak
1000 V AC/DC
1000 V AC/DC
600 V AC/DC
300 V AC/DC
100 mV/A
300 V AC/DC
4 mV/A
30 V DC/ACpeak
30 kV ACpeak
20 mV/kV
5 V
Resistance:
1005 Ω at 25 °C
1530 Ω at 90 °C
R
Measurement system with 8 automatic measurement
functions
$
Mean value
$
Rms value
$
Min
$
Max
$
Peak-to-peak
$
Pulse
$
Duty cycle
$
Frequency
R
Selectable signal range
$
Full curve or between cursors
R
Zoom
$
Selectable curve section for horizontal and verti-
cal enlargement
R
Adjustable cursors with display for
$
x1, x2
$
delta x
$
y1 and y2 (channel 1)
$
y1 and y2 (channel 2)
R
Reference curves
$
Storage, loading, commenting, pre-setting of
scope set-up for live curves
R
Storage functions
$
Scrolling forwards and backwards
R
Search functions e.g. MinMax, duty cycle
Max. output voltage
on measuring lead
60 V
5 V
320 V
60 V
20 V
30 V
300 V
30 V
5 V
5 V
60 V
1 V
1)
5 V
Robert Bosch GmbH