12
Drill chuck
13
Adjustment ring, torque
Handle
14
Only with TruTool HD 1813 (1B5).
3.

Operation

WARNING
Risk of injury from unintentional
actuation of the On/Off switch.
» Remove the rechargeable battery from
the machine before carrying out any
work on the machine!
3.1

Switching on/off

RPMs are infinitely adjustable depending
on the pressure on the On/Off switch.
Switching on
» See Figure 12
Switching off
» See Figure 13
3.2
Changing the rechargeable
battery
The rechargeable battery can be used
immediately upon delivery and can be
charged at any time.
Removing the rechargeable battery
» See Figure 14
Inserting the rechargeable battery
» See Figure 15
3.3
Rechargeable battery charge
status display
When the On/Off switch is actuated,
the rechargeable battery charge status
display shows the rechargeable battery
charge level.
» See Figure 16
22
BA_Bohrschrauber 18 V_2017.indb 22
3.4
Charging the rechargeable
battery
Only use the rechargers recommended by
TRUMPF for charging the rechargeable
batteries.
Observe the information in
the operating instructions for
the recharger used.
3.5

Changing tools

» See Figure 17
3.6

Mounting the handle

TruTool HD 1813 (1B5) only.
» See Figures 18a and 18b
4.

Adjustments

WARNING
Risk of injury
» Make all settings only when the
machine is switched off!
4.1

Changing the direction of rotation

Clockwise
» See Figure 3
Counterclockwise
» See Figure 4
4.2

Changing gears

NOTE
Damage to the device due to incorrect
gear setting.
» Only select the gear when the motor is
stopped.
Gear 1 (Lo) = Low speed range
» See Figure 5
Gear 2 (Hi) = High speed range
» See Figure 6