The output sockets are located on the rear panel. Connect your loads via the output-sockets. The maximum
load per channel is 100 W. Please note that the maximum current must never be exceeded.
Connection with the mains
The electric connection must only be carried out by a qualified electrician!
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

OPERATION

After connecting the device to the mains, the EUROLITE AT-DIMM 3100 DMX starts running. This unit has
two operating modes. It can be run DMX-controlled or as a Stand Alone-unit.
Setting the operation mode
Press MODE to select an operating mode: DMX, MANUAL, ROLL, AUTO.
DMX-CONTROLLED OPERATION
Mode P1 and P2
In DMX-mode, you can either select mode P1 or P2. Press FUNC until the display indicates d-P1. Use UP or
DOWN to switch to P2.

DMX-Protocol

Mode DMX-Value Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6
P1
0-255
P2
0-255
DANGER TO LIFE!
International
L
N
In DMX-mode, the DMX LED indicator lights up.
Fix
Master
Colors
Dimmer
Red
Green
Strobe
No
Speed
Function
Master
Blue
Dimmer
17/36
Fade
No
Speed
Function
Strobe
Fade
Speed
Speed
70064175_V_1_1.DOC