5.2 Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

5.3 DMX-512 control

The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the device or one device with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first device in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first device in the DMX-chain with the DMX-input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last device, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last device.

6. OPERATION

After you connected the device to the mains, the EDX-1 is ready for use.
International
L
N
the devices will not work at all, or will not work properly.
16/34
resistor
00026401.DOC, Version 2.1