Special Features; Replacement Parts - Chamberlain LiftMaster 1000 Manual Del Usuario

Ocultar thumbs Ver también para LiftMaster 1000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53

SPECIAL FEATURES

A. Door within a door connection (all models)
(If this feature is not installed, the jumper must remain intact.) If
installed, the door must be closed during door within a door operation,
and wiring must be correct. Remove jumper from terminal leads.
Replace with contact switch leads as shown.
B. Flashing light connection (all models)
The flashing light can be installed anywhere. Connect FLA230 light
leads to terminals. When the opener is activated, the light will begin to
flash two seconds before the door moves, and continue flashing while
the door is in motion. See flashing light instructions.
C. Coaxial antenna adapter (all models)
A coaxial antenna connection can be used if the transmitter range is
too short. Cut off the existing antenna. Use standard coax cable.
Strip off end of insulation to 250mm. Reposition antenna.
D. Timer for auto close (Models 800, 1000)
Shipped in OFF position. To activate, must install The Protector
System™, then cut diode at control panel. Timer can be set to close
door 60, 120, or 180 seconds after opening (minimum close time is
30 seconds). If the Protector beam is interrupted, auto close time will
reset.
NOTE: Cutting the diode places the unit into a fail-safe mode, and it
will operate only if The Protector System™ is installed.
E. External radio feature (Models 800, 1000)
To supply power to an external radio receiver or accessory.
ACCESSORIES
24
433MHz
27MHz
(1) Model
4330E
750E
(2) Model
4332E
752E
(3) Model
4333E
(4) Model
4335E
(5) Model
747E
727E
(6) Model
78LM
(7) Model
75LM
(8) Model
98LM
(9) Model
760E
(10) Model 1702E
(11) Model 770E
(12) Model FLA230
(13) Model 1703E
(14) Model 16200LM
(15) Model MDL100LM
(16) Model EQL01
(17) Model 9-13-1
WIRING INSTRUCTIONS FOR ACCESSORIES
Lighted Push Button: To opener terminals: Red-1 and White-2.
Outside Keylock: To opener terminals: Red-1 and White-2.
Protector System™: To opener terminals: White-2 and Black-3.
Door Control Panel:To opener terminals: Red-1 and White-2.

REPLACEMENT PARTS

114A2445C-GB
23
Single-Function Remote Control
2-Function Remote Control
(with 1 code switch)
3-Function Remote Control
3-Function Mini Remote Control
Wireless Keyless Entry Keypad
Multi-Function Door Control Panel
Lighted Door Control Button
Motion Detecting Control Panel
Outside Keylock
Outside Quick Release
The Protector System™
Flashing Light Kit
The Chamberlain Arm™
Door-in-door Switch
Mechanical Door Latch Kit
Door Handle Quick Release
Door Reinforcement Bracket
25
- 26
©2003, Chamberlain GmbH
SPECIFICATIONS
Input Voltage...................230-240V, 50Hz
Max. Pull Force ...............1000N (Model 1000)
Power..............................180W (Model 1000)
Normal Torque ................10Nm (Model 1000)
Standby Power................4W
Type ................................DC Permanent lubrication
Volts ................................24 V DC
Length of Travel ..............Adjustable to 5m (with 3m rail + 2m extension)
Travel Rate .....................17cm per second nom., 20-100% ramp
Lamp ...............................1x230V/40W/E27 socket, on when door starts,
Door Linkage...................Adjustable door arm. Pull cord trolley release.
Personal..........................Push button and automatic reversal in down
Electronic ........................Independent up and down force adjustment
Electrical .........................Low voltage push button wiring.
Limit Adjustment .............Electronic
Start Circuit .....................Low voltage push button circuit.
Length (Overall) ..............3,26m (with standard rail)
Headroom Required........40mm
Hanging Weight ..............14,5kg
Billion Code.....................12
Dip Switch ......................1
Keypad ...........................1
Operating Frequency ......433.92MHz or 27.145MHz
Automatic Garage Door Opener . . . . . . . . . . . . . . . . . . . .Models LM1000, LM800, LM600
are in conformity to the applicable sections of Standards . . . . . .EN 300 220-3, EN55014,
per the provisions & all amendments of the EU Directives . . . . . .73/23/EEC, 89/336/EEC
Automatic Garage Door Opener Models LM1000, LM800, and LM600, when installed
and maintained according to all the Manufacturer's instructions in combination with
a Garage Door, which has also been installed and maintained according to all the
Manufacturer's instructions, meet the provisions of EU Directive 89/392/EEC and all
amendments.
THE CHAMBERLAIN GROUP, INC.
Elmhurst, IL 60126
USA
June, 2003
All rights reserved
800N (Model 800), 600N (Model 600)
160W (Model 800), 140W (Model 600)
8Nm (Model 800), 6Nm (Model 600)
Motor
Drive Mechanism
off 2-1/2 minutes after stop. Bulbs not included.
Safety
direction. Push button and automatic stop in up
direction.
screws.
Dimensions
Receiver Code Registers
D e c l a r a t i o n o f C o n f o r m i t y
EN61000-3, ETS 300 683,
EN60555, & EN60335-1
D e c l a r a t i o n o f I n c o r p o r a t i o n
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
conforms to the above Directives and Standards.
Barbara P. Kelkhoff
Manager, Reg. Affairs
Tabla de contenido
loading

Este manual también es adecuado para:

Liftmaster 800Liftmaster 600

Tabla de contenido