BelFox Premium Slider 500 Manual De Instrucciones página 57

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

To adjust the permanent magnets, move the gate to the desired "OPEN" or
"CLOSED" position. Attach the permanent magnets to the rack opposite the
corresponding reed limit switches. By moving the permanent magnets, you can
readjust the end positions of the gate even more precisely. Once the correct
position of the permanent magnets has been found, fix them with a screw in
the hole provided on the gear rack.
The drives are delivered as standard in DIN left (or as you wish).
1 1 8 8 . . F F u u n n c c t t i i o o n n a a n n d d a a d d j j u u s s t t m m e e n n t t o o f f t t h h e e r r e e f f e e r r e e n n c c e e s s w w i i t t c c h h
All Premium Slider 500i / 800i are equipped as standard with a contactless
magnetic switch as reference switch. The magnetic reference switch is fixed in
the console. The permanent magnet included in the accessory pack is attached
according to the instructions included in the accessory pack.
The distance between magnetic switch and magnet must not exceed 10 mm! If
the range of the magnets is not sufficient, a stronger magnet can be used.
The solenoid must be mounted to the rack at any position between the positi-
ons "OPEN" and "CLOSED". If the gate is also used in partial opening mode, the
position of the magnet should be between "CLOSED" and "Partial opening".
23
Tabla de contenido
loading

Este manual también es adecuado para:

Premium slider 500iPremium slider 800Premium slider 800i

Tabla de contenido