• The valve flushes constantly.
Problem:
- Dirt build-up on the solenoid valve or solenoid valve is installed the wrong way round.
- Power is being delivered constantly to the solenoid valve.
Solution:
- Adjust the potentiometers "TEMPO" n and "GAIN" l to a setting in the middle of their range.
- Shut-off the 220-240V power supply.
- If there is no water flowing, order and replace the electronic unit ref. 463000.
- If the water is still flowing, check that the arrow engraved on the side of the solenoid valve
matches the direction of the water flow.
- Clean the solenoid valve using a small screw driver to lift the valve and flush the solenoid valve
at the outlet. Replace the solenoid valve, not forgetting to replace the filter too.
- If the problem persists, order and replace the solenoid valve ref. 463035 (for cross wall models),
ref. 463034 (for recessed models).
• Water is discharged at the vacuum breaker.
Problem:
- The pipe is butted up against the ceramic.
- Dynamic pressure is too high.
- The tube radius is too low (minimal interior radius 40mm).
• Flush volume is too low (no flushing).
Problem:
- Dynamic pressure is too low.
- Supply pipework is too narrow.
- The flush tube angle is at 90°.
MAINTENANCE & CLEANING
• Cleaning chrome and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the tap several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing
them indoors.