TROUBLESHOOTING

Troubleshooting
1
Indicator
blinks.
2
The indicator
is on.
Indicator
stays on even after pressing
3
button.
4
Indicator
blinks.
5
Indicator
stays on.
GYSFLASH 6.12 LITHIUM
Causes
• Polarity reversal
• Battery voltage is too high
• Clamps in short-circuit
Charge failure, battery non recoverable.
Thermal protection.
Charger in sleep mode.
Charge interrupted by pressing
Solutions
• Check that the clamps are properly connected.
• Check that it is a 12V battery.
Change the battery and press
charge.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
Press button
or connect a battery to the char-
ger to exit sleep mode.
Press
again to restart the charge.
.
EN