Technical Data; Preliminary Checks; Base Plate Position - DITEC CROSS3E Manual Para La Instalacion Y La Manutencion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
1.

TECHNICAL DATA

GB
Power supply
Absorption
Thrust
Max run
Opening speed
Closing speed
Acquisition speed
Max door weight
Service class
Min number of
consecutive cycles
Intermittence
Temperature
Degree of protection
Control panel
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
2.1 Standard installation references (fig. 1)
[1]
Radio
[2]
Flashing light
[3]
Key selector
[4]
Geared motor + control panel
[5]
Photocells
[6]
Rubber edge - sensitive edge
[7]
Opening and closing stop
[8]
Connect power supply to an type-approved omnipole
switch with a contact opening gap of no less that 3 mm
(not supplied).
Connection to the grid is made with independent channels
and separated from the connections to the control and
safety devices.
2.2 Geared motor references (fig. 2-3)
[9]
Casing
[10] Control panel
[11] Motor
[12] Transformer
[13] Manual release
[14] Safety micro
[15] Base plate
[16] Line fuse
[17] Pinion
2.3 Accessories
[18] BATK3
[19] LUXK3E
[20] CROSSCRN2
[21] CROSS3TC
[22] CROSS3SF
CROSS3E - IP1780
All manuals and user guides at all-guides.com
Battery kit
Courtesy light kit
Rack
Chain drive kit
Photocell support kit
CROSS3E
230 V~ / 50-60 Hz
1.2 A
150 N
7 m
5.7 m [CROSS3TC]
0.12 - 0.25 m/s
0.12 - 0.25 m/s
0.10 m/s
300 kg
3 - FREQUENT
50
S2 = 15 min
S3 = 50%
-20° C / +55° C
IP24D
73RP
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm).

3.1 Preliminary checks

Check the stability of the wing (derailing and lateral falls) and
the sliding wheels and that the upper guides do not cause any
friction.
The sliding guide must be securely fixed to the ground for the
full length within the doorway and must have no irregularities
that could hinder the movement of the gate.
The opening and closing stops must be fitted.
Note: make sure that the gate can not exit the sliding guides
and fall.
If the gate has slits, make sure they are covered to prevent
shearing points.
Safety device should be installed at the end of the wing to reduce
the collision force.

3.2 Base plate position

-
Insert the anchoring brackets into the base plate [15] and
secure them by means of the nuts provided.
12
Tabla de contenido
loading

Tabla de contenido