Technical Data; Geared Motor References; Preliminary Checks; Geared Motor Installation - DITEC Luxo3B Manual Para La Instalacion Y La Manutencion

Ocultar thumbs Ver también para Luxo3B:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
1.

TECHNICAL DATA

Power supply
Absorption
Motor power
Thrust
Max Run
Opening time
Intermittence
Temperature
Degree of protection
Weight
Electrical Board
Applications
Recommended
dimensions
for INTENSIVE
(100÷200 cycles a day)
Limit dimensions
for frequent use
(30÷60 cycles a day)
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be guar-
anteed with the use of DITEC accessories and safety devices.
2.1 Standard installation references (fig. 1)
[1]
Radio control
[2]
Flashing light
[3]
Key selector
[4]
Connect power supply to an type-approved omnipole
switch with a contact opening gap of no less that 3 mm
(not supplied by us)
[5]
Electrical board
[6]
Geared motor
[7]
Photocells

2.2 Geared motor references

[8]
Tail bracket
[9]
Head bracket
[10] Cover
[11] Release access door
[12] Release
[13] Drive screw cover
[14] Drive screw
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres.

3.1 Preliminary checks

Check that the structure is sufficiently sturdy and that the hinge
pivots are properly lubricated. Provide an opening and closing
stop.
Attention: Luxo3B/3R can only be installed if distance [C] is
either less than 70 mm or equal (fig. 3).
Luxo 3R
Luxo 3B
230 V~ / 50 Hz
230 V~ / 50 Hz
1.1 A
180 W
3000 N
350 mm
350 mm
22 s/90°
22 s/90°
S2 = 20 min.
S2 = 20 min.
S3 = 50%
S3 = 50%
-20° C / +55° C
-20° C / +55° C
IP24D
10.5 kg
LogicA21 - A22
E2 - LogicA21 / A22
m
5
4
3
2
1
100
200 300 400 500

3.2 Geared motor installation

- Position tail bracket [8] on to the pillar to check installation
Note: The installation measurements given in the table in
Figure 3 permit to select the values for [A] and [B] accord-
ing to the desired opening angle and with reference to ex-
isting room and spaces. For proper operation, set [A] and
[B] at values between the minimum and maximum ones
specified in the table (compliance with the measurement
given in the table is recommended).
In order to ensure smooth gate movement, check that meas-
urements [A] and [B] are the same. Increasing [A] reduces the
coming up speed during opening. Increasing [B] diminishes
the coming up speed during closing and improves burglar-
proofing. Reducing [B] increases the extent of gate opening.
Measurements [A] and [B] must in any case be compatible
with the useful travel of the piston so that; if [A] is increased,
[B] must be diminished and vice versa.
- Open the release access door [11] unscrew the screw [F]
11
Luxo 5B
230 V~ / 50 Hz
1.1 A
1.1 A
180 W
180 W
3000 N
3000 N
500 mm
32 s/90°
S2 = 20 min.
S3 = 50%
-20° C / +55° C
IP24D
IP24D
10.5 kg
11 kg
E2 - LogicA21 / A22
m
5
4
3
2
1
kg
measurements (fig. 3) and secure it.
and remove the cover [10]. Unscrew the screw [G] and
remove the drive screw covers [13]. Release the piston if
irreversible (see operating instructions).
10
11
J
F
12
Luxo 5BH
24 V=
12 A
200 W
3000 N
500 mm
20÷30 s/90°
S2 = 20 min.
S3 = 50%
-20° C / +55° C
IP24D
11 kg
LogicC22
kg
100
200 300 400 500
G 13
14
LUXO - IP1684
GB
Tabla de contenido
loading

Este manual también es adecuado para:

Luxo3rLuxo5bLuxo5bh

Tabla de contenido