Technical Data; Preliminary Checks; Gearmotor Installation - DITEC FACIL Serie Manual Para La Instalacion Y La Manutencion

Ocultar thumbs Ver también para FACIL Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
1.

TECHNICAL DATA

Power supply
Absorption
Torque
Opening time
Service life
Intermittence
Temperature
Degree of protection
Control panel
Applications
m = leaf width
kg = leaf weight
Recommended dimensions
Limit dimensions
2.
ILLUSTRATIONS REFERENCES
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
2.1 Standard installation references (fig. 1)
[1]
Radio
[2]
Flashing light
[3]
Key selector switch
[4]
FACIL3E (gearmotor and control panel)
Connect the power supply to an omnipolar switch with a
contact opening distance of at least 3 mm (not supplied)
protected against inadvertent or non-authorised activation.
[5]
FACIL3 (gearmotor only)
[6]
Photocells
[7]
Connector block (not supplied)
2.2 Gearmotor references (fig. 3)
[8]
Control panel (type E2)
[9]
BOXFC1 limit switch (optional)
2.3 Accessories
BATK2
Battery Kit (FACIL3H only)
BOXFC1
Limit switch
FACIL3
230 V~ / 50 Hz
1,2 A
240 Nm
22 s / 90°
3 - FREQUENT
S2 = 15 min
S3 = 25%
-20° C / +55° C
IP54
E2
500 kg
400 kg
300 kg
200 kg
100 kg
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm).

3.1 Preliminary checks

Check that the structure of the gate is sturdy and that the hin-
ges are lubricated.
Check the installation measurements as indicated in the table
of fig. 5.

3.2 Gearmotor installation

-
Securely fix the fastening plate [10] to the gate pillar and
the arm retention bracket [14] to the leaf as indicated in
fig. 5.
-
Remove the lid and fit the gearmotor to the fastening
plate [15] as indicated in fig. 3.
-
Release the gearmotor (see use instructions).
-
Fix the articulated arms and the arm retention bracket as
indicated in fig. 4.
-
The arm articulations must be lubricated and the screws
sufficiently tightened so that they do not impede the mo-
vement of the arms.
-
If necessary adjust screws [11] and [12] on the stop [13]
positioning the leaf in the closed and open position as
indicated in fig. 4.
3.3 Limit switch installation and adjustment
-
Install the BOXFC1 limit switches as indicated in fig. 6
and referring to the related manual.
Adjust the activation of the limit switches by moving the
sliding blocks [16].
-
Make the electrical connections referring to the examples
in the E2 or VIVAH control panel manual.
11
FACIL3E
230 V~ / 50 Hz
1,2 A
240 Nm
22 s / 90°
3 - FREQUENT
S2 = 15 min
S3 = 25%
-20° C / +55° C
IP54
E2 (incorporated)
1
2
3
4
5
m
2,3
GB
FACIL3H
24 V=
6 A
200 Nm
12 ÷ 32 s / 90°
3 - FREQUENT
S2 = 30 min
S3 = 50%
-20° C / +55° C
IP54
VIVAH
FACIL - IP1827
Tabla de contenido
loading

Este manual también es adecuado para:

Facil3hFacil3Facil3e

Tabla de contenido