To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below 27°C
and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
BATTERY PACK PROTECTION LI-ION BATTERY
The battery pack has overload protection that protects it from
being overloaded and helps to ensure long life.
Under extreme stress the battery electronics switch off the
machine automatically. To restart, switch the machine off and
then on again. If the machine does not start up again, the
battery pack may have discharged completely. In this case it
must be recharged in the battery charger.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in accordance
with local, national and international provisions and regulations.
• The user can transport the batteries by road without further
requirements.
• Commercial transport of Lithium-Ion batteries by third parties
is subject to Dangerous Goods regulations. Transport
preparation and transport are exclusively to be carried out by
appropriately trained persons and the process has to be
accompanied by corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and
insulated to prevent short circuit.
• Ensure that battery pack is secured against movement within
packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
Use only AEG accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our AEG service agents (see
our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the machine type printed as well as the six-digit No. on
the label and order the drawing at your local service agents or
directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10,
71364 Winnenden, Germany.
22
ENGLISH
470 410 - BSS18SBL, BSS18S12BL_EN62841.indd 22
470 410 - BSS18SBL, BSS18S12BL_EN62841.indd 22
SYMBOLS
CAUTION! WARNING! DANGER!
Remove the battery pack before starting any work
on the machine.
Please read the instructions carefully before starting
the machine.
Do not dispose electric tools, batteries/rechargeable
batteries together with household waste material.
Electric tools and batteries that have reached the
end of their life must be collected separately and
returned to an environmentally compatible recycling
facility.
Check with your local authority or retailer for
recycling advice and collection point.
n
No-load speed
0
IPM
Impact range
V
Volts
Direct current
European Conformity Mark
Ukraine Conformity Mark
EurAsian Conformity Mark
30.06.2020 12:45:17
30.06.2020 12:45:17