Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Red blinks
+ indicators on
ADDITIONAL INFORMATION ON 12 & 24V MODES
If the device is charged in 24V mode, the condensers' voltage is too high for a 12V battery.
It takes approximately 2 hours to reach the right voltage for the 12V mode.
During this «cooling period», the 12V mode cannot be activated.
If the device is charged in 24V mode, the condensers' voltage is too high for a 12V battery, both
12V and 24V indicators switch on.
Push the ON / OFF button for a while (~4 sec.) to activate the 24V mode.
Or wait a while to activate the 12V mode.

DUTY CYCLE

Leave the machine to cool down between each use, otherwise the device may overheat and get damaged.
Instructions :
- 3 consecutive uses at the maximum
- 20 minutes cooldown between charging.
STARTRONIC 12/24 V
The device is fully charged in 24V while the battery voltage is 12V.
- 24V activated for a 12V battery.
- The device was fully charged using a
+
deeply discharged 24V battery and the
battery voltage dropped below 15V.
Causes
1. Push the ON / OFF button for a while
(~4 sec.) to activate the 24V mode if
the vehicle is fitted with a 24V battery.
2. If the vehicle is fitted with a 12V
battery, remove the clamps to cancel the
operation.
EN