Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Adjustment
Correction is necessary if the temperature measured
at the take off point differs from the temperature set
on the scale. To adjust please see page 25.
Operation 1341XXX
By turning the handle on the left hand side the
thermostatic mixer is opened, closed and the flow
can be changed from tub to shower function.
The temperature is selected by turning the graduated
handle on the right side.
Operation 1361XXX/1366000/137
8000
The mixer is operated by turning the handle on the
left hand side. The green knob limits the rate of flow
to approx. 10 l/min. If a higher water consumtion
is required press the ECOSTOP button and turn
handle further.
The temperature is selected by turning the graduated
handle on the right side.

Temperature limitation

The temperature is limited by the safety check to 38°
C (100° F). If a higher temperature is required, it is
possible to override the safety stop by depressing
the safety button.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Attention!
The mixer is equipped with non return valves.
The non return valves must be checked regularly accor-
ding to DIN EN 1717 in accordance with national or
regional regulations (at least once a year)
8
English
Using the 1361XXX/1366000/13
78000 in conjunction with combination
boilers.
When using the Ecostat with combination boilers,
the Ecostop ring 12 has to be removed (please see
page 26).
If fitting a hand shower remove the water limiter
from the shower.
Using the 1341XXX in conjunction with
combination boilers.
If fitting a hand shower remove the water limiter
from the shower.
If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Test certificate
13241XXX/13261XXX/13278000: MCA
Anti-pollution function
Spare parts (see page 3)
1�
thermoelement
2�
shut off and diverter unit
3�
knob for thermoelement
4�
knob for shut off and diverter unit 96619XXX
5�
aerator cpl.
6�
non return valve
7�
noise reduction
8�
s-unions
9�
escutcheon
10�
safety set for temperature control 95041000
11�
shut off unit
12�
safety set for flow control
13�
filter packing
14�
hose connection
15�
O-ring 20x1
16�
hexagon socket screw M5x25
max. 1 MPa
1,6 MPa
max. 80° C
65° C
20 l/min
WRAS
94282000
96509000
96618XXX
13485000
96737000
96429000
94140000
96467XXX
94149000
95042000
96922000
98556000
98140000
97664000