Before Each Start-Up; How To Start - Craftsman 919.195410 Manual De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6.
After 20 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop.
The compressor is now ready for use.

Before Each Start-Up:

1.
Place On/Auto/Off lever to
"OFF".
2.
Pull regulator knob out, turn
counterclockwise until it stops.
Push knob in to lock in place.
3.
Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect.
D24910
ardous risk of bursting. Check the
manufacturer's maximum pressure
rating for air tools and accessories.
The regulator outlet pressure must
never exceed the maximum pres-
sure rating.

How to Start:

1.
Turn the On/Auto/Off lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and
turn clockwise to increase pres-
sure. When the desired pressure
is reached push knob in to lock
in place. The compressor is
ready for use.
NOTE: Always operate the air com-
pressor in well-ventilated areas free
of gasoline or other combustible
vapors. If the compressor is being
used to operate a sprayer DO NOT
place near the spray area.
16- ENG
Too much air pres-
sure causes a haz-

Capítulos

Tabla de contenido
loading

Tabla de contenido