Motor
This motor has a manual thermal
overload protector. If the motor over-
heats for any reason, the overload
protector will shut off the motor. The
motor must be allowed to cool down
before restarting. To restart:
1.
Place the On/Auto/Off lever in
the Off postion.
2.
Allow the motor to cool.
Reset
Button
3.
Depress the red reset button on
the motor.
4.
Place the On/Auto/Off lever in
the On/Auto postion to restart
the motor.
Pressure Switch - Replacement
Pressure loads
beyond design lim-
its may cause tank rupture or
explosion. Pressure switch opera-
tion is related to motor HP, tank
rating, and safety valve setting. Do
not attempt to adjust, remove, or
defeat the pressure switch, or
change and modify any pressure
control related device. If replace-
ment is necessary the same rated
switch must be used. Contact a
trained service technician for
replacement.
To Replace Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug air compressor.
3.
Remove the regulator ring and
remove the console cover.
Regulator
Ring
4.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5.
Lift retaining clip from handle and
remove handle.
Retaining clip
6.
Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
Regulator
Outlet
Pressure
Gauge
7.
Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
8.
Remove the regulator.
9.
Apply pipe sealant tape to the
nipple.
21- ENG
Cover
Handle
Tank
Pressure
Gauge
Quick
Connect
D24910