Specifications
Performance
Storage and
transportation tenperature ............... -104 °F a 140 °F
Operating temperature: .................... 35.6 °F a 140 °F
Max. ambient temperature .................. 122 °F (50 °C)
Maximum operating pressure ........................145 PSI
Acceptable absolute viscosity
(fluid pumping) ................ 0.40E-3 to 1.75E-3 Ns/m²
Acceptable pH levels (fluid pumping) ............ 4 to 10
Acceptable fluid density
(fluid pumping) ............................1000 ±10% kg/m³
Performance
FBP3-A
0
.9
0
.9
14
14
12
12
10
10
8
8
6
6
4
4
2
2
0
0
0
4
0
4
FBP6-A
0
2.7
0
2.7
20
20
16
16
12
12
8
8
4
4
0
0
0
12
0
12
For parts or assistance, call Flotec Customer Service at 1-262-728-5551
(-40 °C a +60 °C)
(+2 °C a +60 °C)
m 3 / h
1.8
27
3.6
1.8
27
3.6
8
12
16
8
12
16
gal / min.
m 3 / h
5.4
8.2
10.9
5.4
8.2
10.9
24
36
48
24
36
48
gal / min.
6461 1011
6461 1011
Technical Data
Model
Voltage
Amperage
Power
Qmax
Hmax
4.5
4.5
20
20
13.6
13.6
60
60
FBP3-A
FBP6-A
115V ±10%, 60Hz
1.0A
2.1A
120W
250W
5.3 GPM
15.4 GPM
12.8 psi
17.6 psi
3