Saivod ASG0718I Manual Del Usuario página 79

Ocultar thumbs Ver también para ASG0718I:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Configuration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
2. Min. length of connection pipe is 3m.
3. Max. length of connection pipe.
Cooling
capacity
5000Btu/h
(1465W)
7000Btu/h
(2051W)
9000Btu/h
(2637W)
12000Btu/h
(3516W)
18000Btu/h
(5274W)
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
● Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
Max length
of connec-
tion pipe
24000Btu/h
15
28000Btu/h
15
36000Btu/h
15
42000Btu/h
20
48000Btu/h
25
78
Max length
Cooling
of connec-
capacity
tion pipe
25
(7032W)
30
(8204W)
30
(10548W)
30
(12306W)
30
(14064W)
GB