3.2 BUTTONS DETAIL
SETUP MODE (BUTTON NO. 7)
It can be selected after the start up of the machine, by choosing the setup position on the metal/gas commutator, even if there is an active
security.
Five common parameters are reachable in this menu with the trigger mode commutator. Edit each parameter by pressing
As the hidden menu changes are saved by exiting the menu. So move the metal/gas commutator from the setup position to save parameters
change.
Symbol
Name of function
Pre gas time
Post gas time
Spot time
Easy frequency
time
Arc length setting
mode
TRIGGER MODE (BUTTON NO. 7):
Symbol
Name of function
Continuous mode
Impulsional mode
Spot mode
Easy frequency mode
Description
Time when the gas valve is
open before activate the power
contactor and the wire feed.
Time when the gas valve is open
after the end of power cycle.
In spot mode, this is the maximum
time of welding phase. After the
cycle is automatically stopped.
In intermittent mode, this is the
ON and OFF time. The cycle
process switch on and switch off
alternatively during this time.
Choose when the arc length
adjustment button is active. On the
power source (Loc: local) or on the
wire feeder (rc: wirefeeder).
Press to start and release to stop with a possibility to restart welding without
pregas by pressing the trig during the post gas (hot wire mode).
Impulsional mode. First pulse to start welding and 2nd pulse to stop it. Pregas and
Identical as 2T with a control of the welding time adjusted in the "setup mode". If
the trigger is released after the end of this timeout the weld stops properly, on the
Identical as 2T with 2 phases control by timing adjusted in "setup mode" menu.
The first one is a welding phase and the second is a waiting phase (no weld) up to
Other
Text on screen
PrG
PoG
SPt
EFq
SEt
Description
post gas is maintained as long as the trigger is pressed.
other hand, when timeout is reached the weld cycle stops.
a release of trigger.
No action or parameter accessible in this position.
and
Adjustment values
Min
Max
0.0 s
5.0 s
0.0 s
5.0 s
0.1 s
10.0 s
0.5 s
10.0 s
Loc
rc
EN
buttons.
Default
0.2 s
0.2 s
0.5 s
0.5 s
Loc
Text on
screen
2t
4t
SPt
EFq
Oth