Installer Setting - Air Conditioner Fan Operation Interlocked With Ventilation - LG PREMTB10U Manual Del Usuario

Ocultar thumbs Ver también para PREMTB10U:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installer setting – Air conditioner Fan operation interlocked with ventilation
It is a function that sets the availability of air conditioner FAN movement when only the ventila-
tion is running while air conditioner is off, in case of interlock of the air conditioner operation with
the ventilation operation.
INSTALLATION INSTRUCTIONS
If pressing
button long for 3
1
seconds, it enters into Air conditioner
Fan operation interlocked with
ventilation installer setup mode.
- If pressing once shortly, it enters into
user setup mode. Please press more
than 3 seconds for sure.
If moving to room temperature perception
2
sensor selection menu by pressing
button, it indicates as picture below.
3
Set Thermistor value by pressing
button. (00: air-conditioner fan operate very
low, 01: air-conditioner fan off )
Function Code
Setting value
Press
button to save.
4
Pressing
button will exit settings mode.
5
❈ After setup, it automatically gets out of
setup mode if there is no button input for
25 seconds.
❈ When exiting without pressing set button,
the manipulated value is not reflected.
91