INSTALLATION INSTRUCTIONS
80
Installer Setting - Option Function Setting
Setting feature for indoor unit when plasma purification / electric heater / humidifier / elevation
grill / ventilation kit / auxiliary heater is newly installed, or installed unit is removed.
Press the
button for 3 seconds
1
to enter the Thermostat installer
setting
If pressed for a shorter time, it
enters into user setup mode.
Press the
button to select the option
2
function code as pictured below.
3
Select existing condition
of each code by pressing
buttons.
(00: not installed,
01 : installed)
Function Code
Existing condition
❈ In case of indoor unit that has one
more additional stage in the Aux
heater setting.
00: not installed
01: installed - general
02: installed - duct type
Press
button to save.
4
5
Press the
button to exit settings mode.
After setup, it automatically exits after 25
seconds if there is no input. If the
Setting/Cancel button is not pressed, the
mode will not change.
Function
Code
Plasma purification
20
Electric heater
21
Humidifier
22
Elevation grill
23
Ventilation kit
24
Auxiliary heater
25