Workpiece Installation; Error Message; Switching Between Celsius And Fahrenheit - BEGA BETEX BLF 200 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

7.3 Workpiece installation

After pressing 'STOP', place the sensor on the side of the pole.
By pressing 'STOP', the workpiece is demagnetised automatically.
Wear heat-resistant gloves. Place the yoke with the workpiece on a clean surface. If the heater
has a swivel arm, open it up to the safety positioning cam and slide the workpiece off. Install the
workpiece without delay and prevent it from cooling down.

7.4 Error message

If no temperature increase of at least 1ºC is measured within the time pre-set by the manufacturer,
the induction heater automatically switches off. The display blinks and shows 4 hyphens (----). An
alternating, clear beep is sounded. Press STOP to switch off the beep and check whether:
the sensor has been placed on the workpiece
the sensor plug has been inserted in the socket
(Make sure that the – and + of the plug correspond to that of the socket.)
the wiring of the sensor has not been damaged
the surface area of the sensor is clean
the workpiece is within the specifications for the heater as listed in chapter 9
If the sensor is faulty, as a contingency measure, the workpiece can be heated with the time
mode. The temperature needs to be measured with an external thermometer.

7.5 Switching between Celsius and Fahrenheit

The induction heater operates in the temperature units °C or °F.
Follow the procedure below to switch between these two units:
Press and hold the temperature key for 10 seconds. When pressing, a short beep is sounded.
After 10 seconds, another short beep is sounded and the display changes from one
temperature unit to the other.
The heater can now be operated using the newly set temperature unit.
17
Tabla de contenido
loading

Este manual también es adecuado para:

Betex blf 201Betex blf 202Betex blf 203

Tabla de contenido