IAQ Monitor/ English
L/P/S ventilationCFM/P ventilation minimum
valuemaximum valuesave effective percentage
℃.
REC
Press and hold
to enter the automatic recording function. The currently
measured value, setting function and USB connection are
shown during the recording process.
Press and hold
from the display to exit this function.
RESET
Disconnect the power, press and hold the "RESET" button
and then connect the power to restore all settings to the
factory default values.
Function Setting
Press and hold
enter the function setting mode.
Press
There are 7 settings:
1. 12/24 hour mode.
2. Clock setting.
3. Alarm ON/OFF.
4. CO2 alarm high value.
5. CO2 alarm low value.
6. Outdoor CO2.
7. ABC Auto-correct function.
EN-6
until "Rec" appears on the display
again until "Rec" is disappears
and
or
to select the setting modes.
together for 2 seconds to
2016-10-17 V001