Shut off cold and hot water supplies.
IV. Solenoid valve
1. Loosen screw (U1), see Fig. [10].
2. Unscrew screws (U).
3. Unscrew screw (W1) and decrease solenoid
valve (Z) with adapter (W), see Fig. [11].
4. Decrease plate (W2) and pull out solenoid valve (Z) from the
adapter (W).
5. Remove filter (Z1).
Re-assemble in reverse order.
It must be ensured that the interior of the housing is dry.
The solenoid valve (Z) must be turned when inserting into the
adapter (W) in a clockwise direction against the impact.
Make sure that the cartridge seals of the
adapter (W) engage in the grooves on the housing.
Fit screws (W1) and tighten evenly and alternately.
III. Thermostatic cartridge
1. Remove screw (N1) and pull off handle cap (N),
see Fig. [12].
2. Remove screw (O) and pull off scale handle (P).
3. Remove clip (X1).
Problem / Cause / Remedy
Problem
Cause
• Battery without contact
Water does not flow
• Water supply interrupted
• Filter before solenoid valve is
clogged
• Solenoid valve defective
• Mounting mode is active
• Quantity of water too small
• Battery empty
• Battery almost empty
Pulsating water jet
• Solenoid valve defective
Water flows
continuously
• Water supply throttled
Quantity of water too
• Filter for solenoid valve is clogged
small
• Filter in non-return valve is clogged
• Thermostat not adjustet to local
Water temperature
too high or low
pressure
• Non-return valves defective
4. Pull off stop ring (X).
5. Remove adjusting nut (S) with overload unit (S1).
6. With a 22mm open-ended spanner, unscrew and remove
thermoelement (Y).
Re-assemble in reverse order.
The overload unit (S1) (left-hand thread) must be screwed as
far as possible into the adjusting nut (S).
Observe the correct installation position of the stop
ring (X).
Re-adjustment is necessary after every maintenance
operation on the thermostatic cartridge (see Adjustment).
IV. Non-return valve, see spare parts on fold-out
page I.
Screw out complete non-return valve (43 433) and take out
non-return valve (43 432).
Replacement parts, see fold-out page I
( * = special accessories).
Care
For directions on the care of this mixer, please refer to the
accompanying Care Instructions.
Remedy
- Clean contacts, see maintenance cartridge
- Open stop valves
- Clean, see maintenance solenoid valve
- Replace, see maintenance solenoid valve
- Press operation cap twice (doubleclick)
- Examine hose transfer
- Replace, see maintenance cartridge
- Replace, see maintenance cartridge
- Replace, see maintenance solenoid valve
- Open isolating valves, Check supply pipes
- Replace, see maintenance solenoid valve
- Replace, see maintenance check valve
- Adjust thermostatic cartridge, see
adjustment
- Replace, see maintenance non-return valve