GB
Application
Self closing mixers with thermostat are designed for hot water
supply via pressurized storage heater and utilized in this way
to provide the best temperature accuracy. With sufficient
power (from 18 kW or 250 kcal/min) electric or gas instan-
taneous heaters are suitable.
Thermostats cannot be used in connection with low pressure
storage heaters.
All thermostats are adjusted in the plant at a flow pressure on
both sides of 3 bar.
If temperature deviations should exist due to special instal-
lation conditions, then the thermostat is to be adjusted to the
local conditions (see Adjustment).
Specifications
• Minimum flow pressure without downstream
resistances
• Minimum flow pressure with downstream
resistances
• Operating pressure
• Recommended flow pressure
• Test pressure
• Flow rate at 3 bar flow pessure without
downstream resistances:
• Temperature
Hot water inlet:
Recommended (energy saving):
• Hot water end-stop
• Hot water temperature at supply connection min.
2 °C higher than mixed water temperature
• Supply voltage:
6 V-Lithium battery (Type CR-P2)
• Watercourse infinitely variable from 2 - 180 s
(factory setting 15 s)
• Automatic safety stop after 180 s
• Pulsating water jet early indicates battery change
• Type of protection:
• Water connection
• Minimum flow rate
Special accessory, see spare parts fold-out page I.
• Vandalism hampering, ascertainable metal handle
(ref.-no.: 47 639).
• Socket wrench adjustment (ref.-no.: 47 640).
• Thermoelement cartridge for reversed connection, cold left -
hot right, (ref.-no.: 47 657).
• Special wrench (ref.-no.: 19 070) for dismounting
seat (01 460).
• Special wrench (ref.-no.: 19 132) for dismounting flexible
hoses.
Permission and conformity
This product corresponds to the request of the
appropriate EU guidelines.
The agreement assertions can be requested under the
following address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Disposal note
Dispose of battery properly!
Installation
Plaster and tile the wall, excluding the area occupied by the
installation protection.
1. Unscrew screws (A) and keep for mounting retaining cover,
see fold-out page II, Fig. [1].
2. Cut off rough installation protection (B) tile-justified.
3. Fasten retaining cover (C) with screws (A), (C1) and
washer (C2) through the rough installation protection at the
installation box (D), see Fig. [2].
4. Fasten protection chain (E) of retaining cover (C) at cover
plate (G), see Fig. [3].
5. Connect hose (H) to cold water isolating valve (H1),
0,5 bar
see Fig. [4].
6. Connect hose (J) to cold water isolating valve (J1).
1 bar
7. Connect hose (K) to shower connection (K1).
max. 10 bar
Open isolating valves and check connections for leakage!
1 - 5 bar
10 bar
Final installation
approx. 15 l/min.
1. Engage wall plate (G) in the support frame (C) from above
then press it in and down, see Fig. [5].
max. 70 °C
60 °C
2. Fasten wall plate (G) with screw (G1) using the allen key
supplied.
35 °C - 45 °C
Operation
After pressing the operation cap (L) the water flow releases for
the factory set running time of 15 s, see Fig. [6].
After run off of the adjusted time the valve stops the water flow
independently and without recoil.
IP 55
cold - right
hot - left
Setting the running time
= 5 l/min
Warning
Do not stay in the wet area!
Use suitable aid.
To change the running time please proceed as follows:
1. Activate adjusting mode by pressing the operation cap (L),
see Fig. [6].
2. Hold operation cap pressed, the water flow starts 10 s after
pressing.
3. Release operation cap after achieving the desired running
time (2 - 180 s).
4. Confirm adjusted time by pressing the operation cap twice
(doubleclick) within 2 s.
Increasing running time tenfold
• Press the pushbutton cap again twice (double click)
within 2 s following the short water pulse (1 s).
The tenfold running time is confirmed by two short water
pulses (1 s).
The running time will be confirm by a short water pulse (1 s).
If the running time cannot be set, the running time setting is
deactivated. In order to activate the setting time, cartridge
maintenance must be performed, but without replacing the
battery, see description in the Maintenance section.
4