Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
ADL 60-P / ADL 120-P

Control panel

11 Calibration button
For vertical and horizontal contact surfaces.
12 On/Off button
Switches the power tool on and off.
To switch off the measuring instrument, hold
down the button for approx. 3 seconds.
13 Display control panel
12
14 Save button
Saves the currently displayed measured
value (9 storage locations).
Attention: When another value is saved,
the previous 9 measurements are deleted.
15 Reference button
For transferring angles. The display jumps
to 0.0° and REF flashes on the display.
To delete the reference value, switch off
the spirit level.
16 Signal button
Switches the acoustic signal off and on.
If the angle of inclination is on 0°, 45°, 90°
or the last saved value, this is signalled
acoustically. Note: When the angle
reference value (13) is activated, this
becomes the signalling zero point.
17 Unit of measurement button
Switches the units of measurement
in succession: °, in/ft, %. When the
measuring instrument has been switched
on, the display in ° is always active.
18 Light button
Switches the light on and off.
19 Display up
Tabla de contenido
loading

Este manual también es adecuado para:

Adl 120-p

Tabla de contenido