Measurement system
Resolution (nominal)
Flow Rate (Range)
Operating pressure (Max)
Bursting pressure (Min)
Storage temperature (Range)
Storage humidity (Max)
Operating temperature (Range)
Flow resistance
Permissible Viscosity (Range)
Accuracy
Reproducibility (Typical)
Screen
Power Supply
Battery life
Weight
Protection
The liquids compatible with meter are at low viscosity, namely:
Water
Aus 32 (D.E.F., AdBlue
Milk not suitable for human consumption
Diesel fuel
Windscreen
836 828 R. 01/16
14
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Technical data
Hi Flow
Low Flow
Meter COL. BLACK
Flow-rates:
)
®
TURBINE
0.010 l/pulse
0.005 l/pulse
5 ÷ 120 (l/Min.) FOR DIESEL FUEL, WATER.
10 (bar) 145 (psi)
40 (bar)
-20 ÷ + 70 (°C)
95 (% RU)
-10 ÷ + 50 (°C)
0.30 bar at 100 l/min.
2 ÷ 5.35 cSt
±1% after calibration within
10÷90 (l/min.) 2,65÷23,8 (gallons/min) range
±0,3 (%)
Liquid crystals LCD. Featuring:
- 5-figure partial
- 6-figure Reset Total plus x10 / x100
6-figure non reset Total plus x10 / x100
2x1.5 V alkaline batteries size AAA
18 ÷ 36 months
0.25 Kg (included batteries)
IP65