PROPANE SUPPLY
4
INSTALLATION
PROPANE SUPPLY
Propane gas and propane tank(s) are to be furnished by the user.
Use this heater only with a propane vapor withdrawal supply
system. See Chapter 5 of the Standard for Storage and Handling of
Liquefied Petroleum Gas, ANSI/NFPA 58. Your local library or fire
department will have this booklet.
The amount of propane gas ready for use from propane tanks varies.
Two factors decide this amount:
1. The amount of propane gas in tank(s)
2. The temperature of tank(s)
The chart below shows the number of 100 pound (45 kg) tanks
needed to run this heater.
Do not operate this product with any tank smaller than 100 pounds.
Temperature °F (°C)
at tank location
32 (0)
20 (-7)
10 (-12)
0 (-18)
-10 (-23)
-20 (-29)
Less gas is vaporized at lower temperatures. You may need two or
more 100 pound (45 kg) tanks or one larger tank in colder weather.
Your local propane gas dealer will help you select the proper supply
system. The minimum surrounding-air temperature rating for each
heater is -20°F (-29°C).
INSTALLATION
WARNING: Review and understand the warnings
in the Safety Information section, page 2. They are
needed to safely operate this heater. Follow all local
codes when using this heater.
WARNING: Test all gas piping and connections
for leaks after installing or servicing. Never use an
open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming
show a leak. Correct all leaks at once.
1.
Provide propane supply system (see Propane Supply, above).
2. Connect POL fitting on hose/regulator assembly to propane
tank(s). Turn POL fitting counterclockwise into threads on
tank. Tighten firmly using wrench. Tighten regulator with
vent pointing down.
Number of tanks
(150,000 Btu/Hr)
2
2
3
3
(Use larger
tank)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
3. Connect hose to inlet connector. Tighten firmly using a wrench.
IMPORTANT: Extra hose or piping may be used if needed.
Install extra hose or piping between hose/regulator assembly
and propane tank. You must use the regulator supplied with
heater.
4. Open propane supply valve on propane tank(s) slowly.
Note: If not opened slowly, excess-flow check valve on
propane tank may stop gas flow. If this happens, close pro-
pane supply valve and open again slowly.
5. Check all connections for leaks.
WARNING: Never use an open flame to check for
a leak. Apply a mixture of liquid soap and water to all
joints. Bubbles forming show a leak. Correct all
leaks at once.
6. Close propane supply valve.
Supply
Valve
Propane
Tank
Figure 3 - Regulator With Vent Pointing Down
Inlet Connector
Figure 4 - Hose and Inlet Connector
Hose
Regulator
Vent
(pointing down)
POL Fitting
Hose
111855-01A