Pentair ULTRATEMP 70 Guía De Instalación Y Usuario página 18

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

14
Connecting the Heat Pump to the IntelliTouch
Center via the RS-485 Connector
Switch the main power off to the IntelliTouch
EasyTouch
The UltraTemp
Heat Pump can be controlled by an
®
IntelliTouch or EasyTouch system via the RS-485
communication cable. In this configuration, IntelliTouch
or EasyTouch overrides preset Temperature Set points
on the heat pump.
The transfer of this data takes several seconds and
causes a delay from when the command is given from
the IntelliTouch or EasyTouch indoor control panel
until the heat pump physically responds. This happens
automatically but may take 1-2 minutes to complete.
Note: Heat pump control board set points will be
shown as "N/A" and will be functionality disabled.
For more information, refer to the IntelliTouch User's
Guide (P/N 520102) or the EasyTouch User's Guide
(P/N 520584) or the EasyTouch Wireless System
User's Guide (P/N 520688).
Connection from heat pump board to the IntelliTouch
or EasyTouch system is via the optional four-wire cable
(P/N 520199).
Personality Board
Low Voltage
Raceway
Plastic
Grommet
ULTRATEMP
Heat Pump Installation and User' s Guide
®
®
load center before servicing.
IntelliTouch Load Center
or EasyTouch
®
To connect the heat pump board cable to the
or
®
IntelliTouch or EasyTouch load center:
1. Unlatch the IntelliTouch or EasyTouch load center
front door spring latches, and open the front door.
2. Remove the cover-panel screws securing the high
voltage cover-panel, and remove it from the enclosure.
3. Loosen the two control panel access screws and fold
down the outdoor control panel.
4. Insert the four-wire cable into plastic grommet on
the bottom of the enclosure and route the wire up
through the low voltage raceway to the Personality
board.
5. Strip back the cable conductors ¼ in. Insert the wires
into either of the COM PORTS (J7 and J8) screw
terminals located on the left side of the Personality
board. Secure the wires with the screws. For wiring
details, refer to the pin configuration as shown on
page 15.
Note: Multiple wires may be inserted into single
screw terminal.
6. Close the IntelliTouch control panel and secure it with
the two access screws.
7. Install the high voltage panel cover and secure it with
the two retaining screws.
8. Close the load center front door and secure with the
two latches.
9. Switch power on to the IntelliTouch load center.
Access
Screw
Cover
Panel
Screw
(Cover Panel
not shown)
Control System Load
®
Tabla de contenido
loading