To ensure that the appliance operates properly and to reduce
energy consumption, it is important that the appliance is
installed correctly.
Ventilation
The compressor and condenser generate heat and, therefore, need
to be ventilated properly. Rooms with no ventilation are not suited
for installation of the appliance. Therefore, it should be installed in a
room with an opening (window or French window) that provide the
appropriate amount of air re-circulation. It is also important to install
it in a free humidity room.
During installation, make sure not to cover or obstruct the grid that
allow for proper ventilation of the appliance. For proper ventilation of
the appliance, leave a space of at least 10 cm, between the sides of
the appliance and any adjacent cabinets/walls.
Away from heat
Avoid positioning the appliance in a place where it is directly
exposed to sunlight or near an oven, cook top or similar.
Electrical and earth connection
The appliance should not be turned on right after transportation.
Two hours is the advised time so that the oil from the
motor-compressor gets back to its original position.
Before proceeding with the electrical connection, make sure that the
voltage indicated on the rating plate, corresponds to the mains
voltage in your home and that the socket is fitted with a standard
earth wire, in accordance with safety standards. If the socket is not
A Temperature adjustment knob
By turning the knob from setting Min (1) to setting Max (4/5) allows
adjusts the temperature inside the freezer.
For dual temperature appliances, the button can be set to cooler or
freezer function, turning it between +5°C and -25°C.
A1 The fast freezing position *
If present, the position "Super freezing" allows the compressor to
function continuously in order to reach the necessary temperatures
for the rapid freezing of fresh food. When the push button is not
pressed, the freezer is functioning according to the thermostat
regulation.
For optimal appliance performance, set the appliance to super
freeze position 12 to 24 hours before you put the fresh food into the
freezer. "Super Freeze" mode should be deactivated after 24-48
hours in order to save energy.
B Warning Indicator (red light)
When this red warning light comes on for a prolonged period of time,
it means that the freezer is not functioning properly and the
temperature is too high. This warning light may come on for a brief
Before starting the appliance, follow the installation instructions (see
"Safety" and "Installation").
Once the appliance has been connected to the power source, the
green "C" and red "B" lights will turn on (except model with DUAL
function).
APPLIANCES WITHOUT "SUPER FREEZING" FUNCTION:
In models without a "super freeze" function, the orange "D"*
indicator lights up automatically when the compressor is running. In
this condition, after connecting the appliance to the power source,
the "D" light will be active. Then set the selector "A" to the MAX
INSTALLATION
INSTALLATION
THE APPLIANCE
THE APPLIANCE

SETTING UP THE APPLIANCE

SETTING UP THE APPLIANCE
10
EN
fitted with an earth wire, the manufacturer will not be held liability for
any damages and or injuries arising out of the use of the appliance.
Do not use multiple sockets or adapters. Position the appliance in
such a way that you can access the socket where it is plugged in.
Electrical power
The electrical socket must be able to handle the maximum power
load of the appliance, which is indicated on the rating plate located
in the back of the appliance.
This refrigeration appliance is not designed to be used as an
integrated appliance. It must be installed respecting the
conditions indicated in the instruction manual.
To avoid a risk due to the instability of the appliance, you
must follow up to all the instructions.
This appliance must be installed in a place compatible with its
climatic class declared on the data label located on the back
side of the appliance:
Climatic
Symbol
Class
SN
Extended temperate
Temperate
N
Subtropical
ST
Tropical
T
period when the lid is left open for an extended period of time (when
the freezer is being loaded or unloaded).
C Power supply indicator (green light)
The green light will come on and stay on while the appliance is
connected and is operating normally.
D Fast Freeze Indicator / Running Compressor Indicator *
(orange light)
This yellow indicator light will come on when the temperature
adjustment knob is turned to the Super position A1 (if present).
Models without "Super freezing" function this light (if present)
comes on while compressor is running.
F Internal light *
G Defrost water drain system *
H Basket *
I Ventilating grille *
J Wheels or feet * (depending on model)
* Not present in all models
position (4/5). When the red indicator "B" is off, turn the selector "A"
to a middle position (2/3). The freezer can now be used.
The orange "D" light will remain automatically on whenever the
compressor is running.
APPLIANCES WITH "SUPER FREEZING" FUNCTION:
Activate (if available) the "super freezing" function according to
position "A1" (yellow indicator "D" should stay on). When the red
indicator "B" is off, turn off the "Super" function, deactivating the "A1"
position (the yellow indicator "D" should be off), and put the selector
"A" in a middle position. The freezer can now be used.
Minimum
Maximum
ambient
ambient
temperature
temperature
+10
+32ºC
+16
+32ºC
+16
+38ºC
+16
+43ºC