bled off through the air valves. Should the
pressure have risen well above the limit
expected, discharge the over pressure by
opening the pressure-relief valve.
N.B. The OFT/BFT versions are loaded by
means of the special coupling indicated in
figs. 1/a - 1/c
2.5. 1

Emptying the system

Use the drain tap to empty the system (9
fig. 4). Turn off the boiler before doing this.
2.6
FLUES/CHIMNEYS
A chimney or flue for the evacuation of the
combustion products into the atmosphere
must correspond to the requisites prescri-
bed by the laws in force.
In particular, the specific prescriptions of
law relative to boilers with natural draught
in collective pipes (type B) and those for boi-
lers with forced draught (type C) must be
respected.
2.6. 1
Ducting of existing chimneys
To recover or duct existing chimneys, ducts
declared suitable for the purpose by the
manufacturer must be used, and the instal-
lation and use modalities indicated by the
said manufacturer must also be followed
as well as the prescriptions of Standard
UNI 10845.
2.7
INSTALLATION OF COAXIAL
DUCT (versions "BF - BFT")
2.7. 1
Accessories 60/100
The 60/100 coaxial duct is supplied on
request in kit code 8084811.
The diagrams of fig. 5 illustrate some
examples of different types of discharge
modalities allowed and the maximum
For discharge types C12-C42, use the diaphragms supplied with the boiler:
- ø 84.0 for version "20" only when the length of the coaxial duct is less than 2 metres,
- ø 86.0 for version "25-35" only when the length of the coaxial duct is less than 1 metre,
- ø 87.5 for version "30" only when the length of the coaxial duct is less than 2 metres.
For discharge types C32, use the following diaphragms according to the length of the duct and without
additional curves:
Installations with vetrical
extension L. 200 code 8086908 *
"20 BFT" models
Diaphragm
Diaphragm
ø 84
ø 86
(code 6028622) (code 6028623)
L max = 4 m
L max = 5 m
"25 BF - 25 BFT - 30 BF - 35 BF" models
Diaphragm
Diaphragm
ø 86
ø 87,5
(code 6028623) (code 6028624)
L max = 2.5 m
L max = 4 m
* Minimum length of duct L = 1.3 m.
x + y = max 5,0 m per vers. "20"
x + y = max 3,5 m per vers. "25"
x + y = max 3,0 m per vers. "30-35"
IMPORTANT:
– Each additional 90° cur ve
installed reduces the available
length by 1.0 metres.
– Each additional 45° cur ve
installed reduces the available
length by 0.50 metres.
- The insertion of the condensa-
tion collector (8) is obligatory
for vertical stretches of more
than 1.3 metres.
KEY
1
Coaxial flue kit L. 810 code 8084811
2 a Extension L. 1000 code 8096103
2 b Extension L. 500 code 8096102
3
Vertical extension L. 200 code 8086908
4
Additional 90° curve code 8095801
6
Articulated tile code 8091300
7
Roof outlet terminal L. 1284 code 8091200
8
Vertical condensation collector L. 200 code 8092803
lengths that can be reached.
2.7.2
Diaphragm for 60/100
coaxial duct
The boiler is supplied with a diaphragm of
Installations with vertical condensation
collector code 8092803 *
"20 BFT" models
Without
Diaphragm
diaphragm
ø 84
(code 6028622) (code 6028623)
----
L max = 3 m
"25 BF - 25 BFT - 30 BF - 35 BF" models
Without
Diaphragm
diaphragm
ø 86
(code 6028623) (code 6028624)
L max = 5 m
---
x
2
4
y
3
C42
max 5,0 m per vers. "20"
max 3,5 m per vers. "25"
max 3,0 m per vers. "30-35"
C12
84 (version 20 BFT), 86 (versions 25-35
BF/25 BFT) and 87.5 (version 30 BF). The
diaphragms 87.5 (code 6028824) and 86
(code 6028623) can be requested separa-
tely. Use the diaphragms according to the
indications of fig. 5/a.
Diaphragm
Without
ø 86
diaphragm
L max = 5 m
---
Diaphragm
Without
ø 87,5
diaphragm
L max = 2.5 m
L max = 4 m
7
6
2
3
8
C32
1
Fig. 5
Fig. 5/a
ES
PT
GB
79